<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">475803515</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123744.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20000201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s002689910035</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s002689910035</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Endoscopic Ultrasonography of the Esophagus</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Morimichi Fukuda, Kenichiro Hirata, Hiroshi Natori]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Endoscopic ultrasonography (EUS) is a generally accepted technique for the preoperative staging of malignant tumors in the upper and lower gastrointestinal tracts. In particular, EUS has been considered the method of choice in diagnosing esophageal carcinoma due to the relative ease in performing the examination and the accuracy of staging based on high-resolution ultrasonic imaging from within the lumen of the esophagus. This comprehensive review covers currently available EUS instruments, image characteristics of esophageal carcinoma, and images by the recently introduced miniprobe scanner. The role of the method in diagnosing superficial esophageal carcinoma and the possible treatment by endoscopic mucosal resection of this particular disease entity are discussed.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">by the Société Internationale de Chirurgie, 2000</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Fukuda</subfield>
   <subfield code="D">Morimichi</subfield>
   <subfield code="u">Department of Diagnostic Ultrasound and Medical Electronics, Sapporo Medical University Hospital, Minami 1-jo, Nishi 16-chome, Chuo-ku, Sapporo, Hokkaido, Japan, JP</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hirata</subfield>
   <subfield code="D">Kenichiro</subfield>
   <subfield code="u">Department of Diagnostic Ultrasound and Medical Electronics, Sapporo Medical University Hospital, Minami 1-jo, Nishi 16-chome, Chuo-ku, Sapporo, Hokkaido, Japan, JP</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Natori</subfield>
   <subfield code="D">Hiroshi</subfield>
   <subfield code="u">Department of Diagnostic Ultrasound and Medical Electronics, Sapporo Medical University Hospital, Minami 1-jo, Nishi 16-chome, Chuo-ku, Sapporo, Hokkaido, Japan, JP</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">World Journal of Surgery</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">24/2(2000-02-01), 216-226</subfield>
   <subfield code="x">0364-2313</subfield>
   <subfield code="q">24:2&lt;216</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">24</subfield>
   <subfield code="o">268</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s002689910035</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s002689910035</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Fukuda</subfield>
   <subfield code="D">Morimichi</subfield>
   <subfield code="u">Department of Diagnostic Ultrasound and Medical Electronics, Sapporo Medical University Hospital, Minami 1-jo, Nishi 16-chome, Chuo-ku, Sapporo, Hokkaido, Japan, JP</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hirata</subfield>
   <subfield code="D">Kenichiro</subfield>
   <subfield code="u">Department of Diagnostic Ultrasound and Medical Electronics, Sapporo Medical University Hospital, Minami 1-jo, Nishi 16-chome, Chuo-ku, Sapporo, Hokkaido, Japan, JP</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Natori</subfield>
   <subfield code="D">Hiroshi</subfield>
   <subfield code="u">Department of Diagnostic Ultrasound and Medical Electronics, Sapporo Medical University Hospital, Minami 1-jo, Nishi 16-chome, Chuo-ku, Sapporo, Hokkaido, Japan, JP</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">World Journal of Surgery</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">24/2(2000-02-01), 216-226</subfield>
   <subfield code="x">0364-2313</subfield>
   <subfield code="q">24:2&lt;216</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">24</subfield>
   <subfield code="o">268</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
