<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">475813316</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123803.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20000301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s000240050006</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s000240050006</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Groundwater, Radon Continuous Monitoring System (α-scintillation Counting) for Natural Hazard Surveillance</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[G. Galli, C. Mancini, F. Quattrocchi]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">—A &quot;quasi continuous mode” monitoring system to measure the radon concentration within a natural environment (mainly groundwater), was designed, assembled and tested, under collaboration between DINCE and ING, partly within the framework of two EC funded programs.¶The radon monitor consists of a customised discrete automatic sampler which produces a gas flux circuit, and an economical α-scintillation cell, coupled with a reliable electronics-photomultiplier assemblage. A convenient calibration system together with a temporised control system have been set up. The overall &quot;mean efficiency” of the system was calculated to be 7.79±0.13 counts per minute (cpm) for each Bq/L.¶Taking into consideration the present and future requirements of a geochemical surveillance network to assess natural hazards, the prototype design evolved from the study of existing systems devoted to monitor radon concentration levels, which are critically reviewed within this paper.¶In response to the main prerequisite of a remote station: maximum remote sensor versatility preserving shared software and hardware for the network as a whole, this radon monitoring system was conceived as part of a multi-parametric Geochemical Monitoring System (GMS II) prototype, designed and realised as a test-stand for sensors (chemical, hydrological, geophysical, organic chemistry devoted, etc.) in continuous evolution throughout the international market.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Birkhäuser Verlag Basel,, 2000</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Key Words: Continuous radon monitor prototype, review of methods, seismic, volcanic and environmental surveillance</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Galli</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="u">Dipartimento di Ingegneria Nucleare, Universita' la Sapienza di Roma (DINCE), Piazza S. Pietro in Vincoli, 10, 00185, Roma, Italy., IT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Mancini</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Dipartimento di Ingegneria Nucleare, Universita' la Sapienza di Roma (DINCE), Piazza S. Pietro in Vincoli, 10, 00185, Roma, Italy., IT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Quattrocchi</subfield>
   <subfield code="D">F.</subfield>
   <subfield code="u">Istituto Nazionale di Geofisica (ING), Via di Vigna Murata 605, 00143, Roma, Italy, e-mail: quattrocchi@ing750.ingrm.it, IT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s000240050006</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s000240050006</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Galli</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="u">Dipartimento di Ingegneria Nucleare, Universita' la Sapienza di Roma (DINCE), Piazza S. Pietro in Vincoli, 10, 00185, Roma, Italy., IT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Mancini</subfield>
   <subfield code="D">C.</subfield>
   <subfield code="u">Dipartimento di Ingegneria Nucleare, Universita' la Sapienza di Roma (DINCE), Piazza S. Pietro in Vincoli, 10, 00185, Roma, Italy., IT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Quattrocchi</subfield>
   <subfield code="D">F.</subfield>
   <subfield code="u">Istituto Nazionale di Geofisica (ING), Via di Vigna Murata 605, 00143, Roma, Italy, e-mail: quattrocchi@ing750.ingrm.it, IT</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
