<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">475816080</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123810.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20000501xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1023/A:1003964304448</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1023/A:1003964304448</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Cleaning of copper foil coated with sodium hexanoate as corrosion inhibitor</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[N. Bellakhal, K. Draou, A. Addou, J.L. Brisset]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Sodium hexanoate is proposed as corrosion inhibitor for copper when the metal is situated in an aggressive aqueous or gaseous environment. The efficiency of the inhibitor, measured by electrochemical techniques in the ASTM 1384 standard solution, depends on the hexanoate concentration. Copper foils immersed in a (0.1 M) sodium hexanoate conditioning bath, and later exposed to a strongly oxidizing gliding arc plasma in humid air, yield oxide layers, the thickness and the nature of which differ from the unconditioned samples since the voltammograms show no CuO at the surface. The organic salt thus limits the oxidation process induced by the gaseous species. The organic layer remains active for at least 30 min. For longer exposures, the salt begins to degrade to carbon dioxide, which makes the plasma treatment a useful tool to clean metallic surfaces.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Kluwer Academic Publishers, 2000</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">copper</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">corrosion inhibitor</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">gliding arc plasma</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">humid air plasma</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">non-thermal plasma</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">sodium hexanoate</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">surface cleaning</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Bellakhal</subfield>
   <subfield code="D">N.</subfield>
   <subfield code="u">Laboratoire d'Electrochimie Interfaciale et de Chimie Analytique, Université de Rouen, 76821, Mont Saint Aignan Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Draou</subfield>
   <subfield code="D">K.</subfield>
   <subfield code="u">Laboratoire d'Electrochimie Interfaciale et de Chimie Analytique, Université de Rouen, 76821, Mont Saint Aignan Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Addou</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Département de Chimie, Université de Mostaganem, Chemin des Crêtes, Mostaganem, Algeria</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Brisset</subfield>
   <subfield code="D">J.L.</subfield>
   <subfield code="u">Laboratoire d'Electrochimie Interfaciale et de Chimie Analytique, Université de Rouen, 76821, Mont Saint Aignan Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Applied Electrochemistry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">30/5(2000-05-01), 595-600</subfield>
   <subfield code="x">0021-891X</subfield>
   <subfield code="q">30:5&lt;595</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">30</subfield>
   <subfield code="o">10800</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1023/A:1003964304448</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1023/A:1003964304448</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Bellakhal</subfield>
   <subfield code="D">N.</subfield>
   <subfield code="u">Laboratoire d'Electrochimie Interfaciale et de Chimie Analytique, Université de Rouen, 76821, Mont Saint Aignan Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Draou</subfield>
   <subfield code="D">K.</subfield>
   <subfield code="u">Laboratoire d'Electrochimie Interfaciale et de Chimie Analytique, Université de Rouen, 76821, Mont Saint Aignan Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Addou</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Département de Chimie, Université de Mostaganem, Chemin des Crêtes, Mostaganem, Algeria</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Brisset</subfield>
   <subfield code="D">J.L.</subfield>
   <subfield code="u">Laboratoire d'Electrochimie Interfaciale et de Chimie Analytique, Université de Rouen, 76821, Mont Saint Aignan Cedex, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Applied Electrochemistry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">30/5(2000-05-01), 595-600</subfield>
   <subfield code="x">0021-891X</subfield>
   <subfield code="q">30:5&lt;595</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">30</subfield>
   <subfield code="o">10800</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
