<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">47581651X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123811.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20001101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1023/A:1026557830268</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1023/A:1026557830268</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Water splitting at ion-exchange membranes and potential differences in soil during electrodialytic soil remediation</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[L.M. Ottosen, H.K. Hansen, C.B. Hansen]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The optimum current for electrodialytic soil remediation occurs when the limiting current of the anion-exchange membrane is exceeded while that for the cation-exchange membrane is not. At this current, an acidic front will pass through the soil from the anion-exchange membrane towards the cathode, and the polluting heavy metals will be mobilized in the acidic environment. At the same time no production of base will occur from the cation-exchange membrane. A basic environment causes precipitation of hydroxides in the soil next to the cation-exchange membrane, and this will give an increase in voltage drop in the system and furthermore hinder the transport of the heavy metals out of the soil. When the acidic front passes through the soil, the voltage drop will decrease, and the end of the remediation can be predicted by the decrease in voltage to a very low level between the working electrodes.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Kluwer Academic Publishers, 2000</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">copper</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">electrochemical soil remediation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">limiting current</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">soil pH</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ottosen</subfield>
   <subfield code="D">L.M.</subfield>
   <subfield code="u">Department of Geology and Geotechnical Engineering, Technical University of Denmark, Building 204, 2800, Lyngby, Denmark</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hansen</subfield>
   <subfield code="D">H.K.</subfield>
   <subfield code="u">Department of Geology and Geotechnical Engineering, Technical University of Denmark, Building 204, 2800, Lyngby, Denmark</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hansen</subfield>
   <subfield code="D">C.B.</subfield>
   <subfield code="u">Department of Geology and Geotechnical Engineering, Technical University of Denmark, Building 204, 2800, Lyngby, Denmark</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Applied Electrochemistry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">30/11(2000-11-01), 1199-1207</subfield>
   <subfield code="x">0021-891X</subfield>
   <subfield code="q">30:11&lt;1199</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">30</subfield>
   <subfield code="o">10800</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1023/A:1026557830268</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1023/A:1026557830268</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ottosen</subfield>
   <subfield code="D">L.M.</subfield>
   <subfield code="u">Department of Geology and Geotechnical Engineering, Technical University of Denmark, Building 204, 2800, Lyngby, Denmark</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hansen</subfield>
   <subfield code="D">H.K.</subfield>
   <subfield code="u">Department of Geology and Geotechnical Engineering, Technical University of Denmark, Building 204, 2800, Lyngby, Denmark</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hansen</subfield>
   <subfield code="D">C.B.</subfield>
   <subfield code="u">Department of Geology and Geotechnical Engineering, Technical University of Denmark, Building 204, 2800, Lyngby, Denmark</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Applied Electrochemistry</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">30/11(2000-11-01), 1199-1207</subfield>
   <subfield code="x">0021-891X</subfield>
   <subfield code="q">30:11&lt;1199</subfield>
   <subfield code="1">2000</subfield>
   <subfield code="2">30</subfield>
   <subfield code="o">10800</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
