<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">475842553</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180406123905.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170329e20001001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/PL00011839</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/PL00011839</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Improving the cervical spine X-ray in trauma patients utilizing dynamic range compression (DRC) modified digital radiography</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[T. Janchar, D. Artz, D. Milzman, M. Freedman]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Purpose: Inadequate cervical spine X-rays delay diagnosis and treatment and add radiation exposure to trauma patients with suspected cervical spine injury. Digital radiography (DR) with dynamic range compression (DRC) modification can improve the visualization of abnormalities in the cervical spine X-ray. Methods: Two digital hard copy cervical spine X-rays from each of 65 trauma patients were used, both with standard DR processing, and with the second image having the DRC algorithm applied. Blinded readers from emergency medicine, surgery, radiology, and critical care specialties evaluated the films with data analyzed by Student's t-test and ϰ2; P &lt; 0.05. Results: Readers cleared more of the DRC than of the non-DRC images: 41 % vs 30 %, P &lt; 0.001. More vertebral bodies were visualized on DRC than on non-DRC images: 65 % vs 53 % showing C7, P &lt; 0.001. For overall impression of the image quality, DRC images rated higher on a 10-cm visual analog scale than non-DRC: 6.7 vs 4.2, P &lt; 0.001. Conclusions: DRC modification of DR images enabled physicians to evaluate cervical spine X-rays more rapidly and accurately after trauma, requiring fewer repeat films.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">American Society of Emergency Radiology, 2000</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Key words Trauma - Cervical spine - Digital - Radiography</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Janchar</subfield>
   <subfield code="D">T.</subfield>
   <subfield code="u">Georgetown University Department of Emergency Medicine, Washington DC, USA, US</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Artz</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Georgetown University Department of Radiology, Washington DC, USA, US</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Milzman</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Georgetown University Department of Emergency Medicine, Washington DC, USA, US</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Freedman</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Georgetown University Department of Radiology, Washington DC, USA, US</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/PL00011839</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/PL00011839</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Janchar</subfield>
   <subfield code="D">T.</subfield>
   <subfield code="u">Georgetown University Department of Emergency Medicine, Washington DC, USA, US</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Artz</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Georgetown University Department of Radiology, Washington DC, USA, US</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Milzman</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Georgetown University Department of Emergency Medicine, Washington DC, USA, US</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Freedman</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Georgetown University Department of Radiology, Washington DC, USA, US</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
