<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">477034616</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405111302.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170330e19960101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s002689900004</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s002689900004</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Value of Bronchoscopic Pneumonia Diagnosis: Prospective Study</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[A. Prokop, M. Gawenda, I. Krüger, H. Pichlmaier]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Abstract. In a prospective clinical study we examined whether bronchoscopically controlled suctioning is preferable to the blind suctioning of mucus aspirates for bacterial identification of intensive care unit patients with pneumonia. Forty patients with clinical and radiologic signs of pneumonia underwent both bronchoscopically controlled and blind endotracheal lavage. Bronchoscopically controlled suctioning did not demonstrate greater sensitivity for identifying organisms than the results obtained from blind suctioning (58 organism were bronchoscopically identified, compared to 57 organisms identified by blind suctioning;: p = 0.32, NS). Arterial and mixed venous partial oxygen pressure and shunt also showed no significant differences 15 minutes before and after examination, nor did the blood pressure or pulse. The use of four of the bronchoscopes resulted in preinterventional contamination with Pseudomonas . Bronchoscopically controlled lavage shows no advantages over blind endotracheal lavage for diagnosing pneumonia. Blind suctioning with single-use sterile catheters can be done more quickly and inexpensively with fewer personnel and a lower complication rate.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">1996 by the Société Internationale de Chir, ugie</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Prokop</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Department of Surgery, University of Cologne, Joseph-Stelzmann-Strasse 9, W-50924 Cologne, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Gawenda</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Department of Surgery, University of Cologne, Joseph-Stelzmann-Strasse 9, W-50924 Cologne, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Krüger</subfield>
   <subfield code="D">I.</subfield>
   <subfield code="u">Department of Surgery, University of Cologne, Joseph-Stelzmann-Strasse 9, W-50924 Cologne, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Pichlmaier</subfield>
   <subfield code="D">H.</subfield>
   <subfield code="u">Department of Surgery, University of Cologne, Joseph-Stelzmann-Strasse 9, W-50924 Cologne, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s002689900004</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s002689900004</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Prokop</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Department of Surgery, University of Cologne, Joseph-Stelzmann-Strasse 9, W-50924 Cologne, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Gawenda</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Department of Surgery, University of Cologne, Joseph-Stelzmann-Strasse 9, W-50924 Cologne, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Krüger</subfield>
   <subfield code="D">I.</subfield>
   <subfield code="u">Department of Surgery, University of Cologne, Joseph-Stelzmann-Strasse 9, W-50924 Cologne, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Pichlmaier</subfield>
   <subfield code="D">H.</subfield>
   <subfield code="u">Department of Surgery, University of Cologne, Joseph-Stelzmann-Strasse 9, W-50924 Cologne, Germany, DE</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
