<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">477061982</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405111403.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170330e19961201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF00133081</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF00133081</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Advances in the monitoring of oral anticoagulation: Point-of-care testing, patient self-monitoring, and patient self-management</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Katharine Leaning, Jack Ansell]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Oral anticoagulation with warfarin sodium has proven to be an effective therapy for patients at risk for thromboembolic disease, but due to its high risk/benefit ratio, many physicians are reluctant to prescribe the drug. The development of capillary whole-blood prothrombin time (PT) monitors provides a potential means to decrease this risk/benefit ratio and to encourage the use of warfarin. Studies show that this technology is accurate, precise, and correlates closely with standard laboratory methods. Given that these monitors are simple and portable, investigators have conducted studies to determine their suitability for patient self-testing and home monitoring. Investigations show that patients can accurately and precisely perform the PT test at home, and that this mode of therapy appears to be at least as safe and effective as standard management. Furthermore, limited studies also suggest that patients can also manage their own dosing based on personalized guidelines designed by a physician. Given the theoretical potential for improved patient outcomes and overall cost reduction, patient self-monitoring and self-management are not far off. Large randomized prospective trials are now needed to confirm that the future of anticoagulation management should include patient self-monitoring and patient self-management of therapy.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Kluwer Academic Publishers, 1996</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">oral anticoagulation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">warfarin</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">point-of-care testing</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">prothrombin time</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">self-management</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Leaning</subfield>
   <subfield code="D">Katharine</subfield>
   <subfield code="u">Department of Medicine, Boston University School of Medicine, Boston, Massachusetts, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ansell</subfield>
   <subfield code="D">Jack</subfield>
   <subfield code="u">Department of Medicine, Boston University School of Medicine, Boston, Massachusetts, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Thrombosis and Thrombolysis</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">3/4(1996-12-01), 377-383</subfield>
   <subfield code="x">0929-5305</subfield>
   <subfield code="q">3:4&lt;377</subfield>
   <subfield code="1">1996</subfield>
   <subfield code="2">3</subfield>
   <subfield code="o">11239</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF00133081</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF00133081</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Leaning</subfield>
   <subfield code="D">Katharine</subfield>
   <subfield code="u">Department of Medicine, Boston University School of Medicine, Boston, Massachusetts, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ansell</subfield>
   <subfield code="D">Jack</subfield>
   <subfield code="u">Department of Medicine, Boston University School of Medicine, Boston, Massachusetts, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Thrombosis and Thrombolysis</subfield>
   <subfield code="d">Kluwer Academic Publishers</subfield>
   <subfield code="g">3/4(1996-12-01), 377-383</subfield>
   <subfield code="x">0929-5305</subfield>
   <subfield code="q">3:4&lt;377</subfield>
   <subfield code="1">1996</subfield>
   <subfield code="2">3</subfield>
   <subfield code="o">11239</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
