<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">477080502</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405111448.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170330e19961201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF00732042</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF00732042</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Nondisruptive material sampling and mechanical testing</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[J. Foulds, R. Viswanathan]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The aging and inservice degradation of industrial equipment has underscored a need for efficient and reliable evaluation of the suitability of such equipment for continued service. The structural components of traditional energy production facilities, such as fossil- and nuclear-fueled electric power plants, are prime examples of aging equipment for which integrity during extended service is of major concern. The paper describes a recently developed nondisruptive miniature material sample removal and test approach that is being applied to a range of operating electric power plant components from turbine generators to pressure vessels, and to petrochemical plant reactor vessels for inservice integrity assessment. Thein situ removal of a thin wafer-like sample (less than 25 mm in diameter and 2.5 mm in thickness) from the component surface generally has no effect on component integrity. The miniature specimen small punch (disk bend) test has been developed to mechanically test the as-removed material, and is being used to estimate the material tensile behavior and fracture properties (ductile-to-brittle transition temperature and fracture toughness) required for a reliable component integrity assessment.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Plenum Publishing Corporation, 1996</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Miniature sample removal</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">fracture toughness</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">small punch testing</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">disk bend</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">continuum toughness</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">steels</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">fracture appearance transition temperature</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">inservice integrity</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Foulds</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Failure Analysis Associates, Inc., 149 Commonwealth Drive, 94025, Menlo Park, California</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Viswanathan</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Electric Power Research Institute, 3412 Hillview Avenue, 94303, Palo Alto, California</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Nondestructive Evaluation</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">15/3-4(1996-12-01), 151-162</subfield>
   <subfield code="x">0195-9298</subfield>
   <subfield code="q">15:3-4&lt;151</subfield>
   <subfield code="1">1996</subfield>
   <subfield code="2">15</subfield>
   <subfield code="o">10921</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF00732042</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF00732042</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Foulds</subfield>
   <subfield code="D">J.</subfield>
   <subfield code="u">Failure Analysis Associates, Inc., 149 Commonwealth Drive, 94025, Menlo Park, California</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Viswanathan</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Electric Power Research Institute, 3412 Hillview Avenue, 94303, Palo Alto, California</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Nondestructive Evaluation</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">15/3-4(1996-12-01), 151-162</subfield>
   <subfield code="x">0195-9298</subfield>
   <subfield code="q">15:3-4&lt;151</subfield>
   <subfield code="1">1996</subfield>
   <subfield code="2">15</subfield>
   <subfield code="o">10921</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
