<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">477080588</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405111448.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170330e19960301xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF00733822</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF00733822</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="4">
   <subfield code="a">The excitation of Lamb waves in pipes using dry-coupled piezoelectric transducers</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[D. Alleyne, P. Cawley]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The development of a dry-coupled piezoelectric transducer system for the detection of corrosion in chemical plant pipework using cylindrical Lamb waves is described. It is shown that the axisymmetricL(0,2) mode at a frequency of about 70 kHz is an attractive mode to use for longdistance propagation. The results show that a ring of piezoelectric length-expander elements can be used to excite theL(0,2) mode and to suppress all the nonaxisymmetric modes. Tests have been carried out both with the piezoelectric elements bonded to the pipe and fabricated into a simple transducer which was clamped against the pipe. The performance of the dry-coupled system was very similar to that of the bonded elements. In pulse echo tests, the noise floor obtained with the dry-coupled system was less than 1% of the amplitude of the propagatingL(0,2) mode. The drycoupled transducers provide a simple, light, readily detachable system for the long-range inspection of pipework.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Plenum Publishing Corporation, 1996</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Pipework</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">corrosion</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Lamb waves</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">dry-coupled transducers</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Alleyne</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Department of Mechanical Engineering, Imperial College, SW7 2BX, London, UK</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Cawley</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Department of Mechanical Engineering, Imperial College, SW7 2BX, London, UK</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Nondestructive Evaluation</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">15/1(1996-03-01), 11-20</subfield>
   <subfield code="x">0195-9298</subfield>
   <subfield code="q">15:1&lt;11</subfield>
   <subfield code="1">1996</subfield>
   <subfield code="2">15</subfield>
   <subfield code="o">10921</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF00733822</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF00733822</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Alleyne</subfield>
   <subfield code="D">D.</subfield>
   <subfield code="u">Department of Mechanical Engineering, Imperial College, SW7 2BX, London, UK</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Cawley</subfield>
   <subfield code="D">P.</subfield>
   <subfield code="u">Department of Mechanical Engineering, Imperial College, SW7 2BX, London, UK</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Nondestructive Evaluation</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">15/1(1996-03-01), 11-20</subfield>
   <subfield code="x">0195-9298</subfield>
   <subfield code="q">15:1&lt;11</subfield>
   <subfield code="1">1996</subfield>
   <subfield code="2">15</subfield>
   <subfield code="o">10921</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
