<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">477124119</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405111644.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170330e19970401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02677948</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02677948</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Thermistor controlled gunn oscillator at Ka-band</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[R. Dixit, Bani Hazra, A. Kush]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Frequency drift of Gunn oscillators is a major cause of concern in most of the Millimeter wave communication systems. This paper describes a simple and cost effective technique to arrest the frequency drift of a Ka band Gunn oscillator within 15 MHz for the operating temperature range of 0°C to 60°C as against a typical drift of about 50 to 100 MHz for free running Gunn oscillator for the same temperature range. At the ambient, the oscillator remains within ±1 MHz from switching on to stabilization. The temperature variation is sensed with a small thermistor bead placed close to the diode and a correction voltage is applied to the bias to compensate for the frequency drift. This compensation circuit also takes into account the non-linear behaviour of the thermistor and the Gunn oscillator with the temperature.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Plenum Publishing Corporation, 1997</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Dixit</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Defence Electronics Applications Laboratory, Raipur Road, 248 001, Dehradun</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hazra</subfield>
   <subfield code="D">Bani</subfield>
   <subfield code="u">Defence Electronics Applications Laboratory, Raipur Road, 248 001, Dehradun</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kush</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Defence Electronics Applications Laboratory, Raipur Road, 248 001, Dehradun</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">International Journal of Infrared and Millimeter Waves</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">18/4(1997-04-01), 859-864</subfield>
   <subfield code="x">0195-9271</subfield>
   <subfield code="q">18:4&lt;859</subfield>
   <subfield code="1">1997</subfield>
   <subfield code="2">18</subfield>
   <subfield code="o">10762</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02677948</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02677948</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Dixit</subfield>
   <subfield code="D">R.</subfield>
   <subfield code="u">Defence Electronics Applications Laboratory, Raipur Road, 248 001, Dehradun</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hazra</subfield>
   <subfield code="D">Bani</subfield>
   <subfield code="u">Defence Electronics Applications Laboratory, Raipur Road, 248 001, Dehradun</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kush</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Defence Electronics Applications Laboratory, Raipur Road, 248 001, Dehradun</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">International Journal of Infrared and Millimeter Waves</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">18/4(1997-04-01), 859-864</subfield>
   <subfield code="x">0195-9271</subfield>
   <subfield code="q">18:4&lt;859</subfield>
   <subfield code="1">1997</subfield>
   <subfield code="2">18</subfield>
   <subfield code="o">10762</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
