<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">477124496</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405111645.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170330e19970201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02677931</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02677931</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Zhang</subfield>
   <subfield code="D">HeBe</subfield>
   <subfield code="u">Institute of Applied Electronics, China Academy of Engineering Physics, P.O. Box 527, Postcode 610003, Chengdu, China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="4">
   <subfield code="a">The cold quality Qcold for magnicon on resonator in the rotating TMn10 mode</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[HeBe Zhang]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Cold quality Qcold is an important parameter in microwave electronic tube design. Magnicon works in a rotrating TMn10 mode in the cylindracl cavity, its field distribution is different from the static state. But up to now researchers simply assume its cold quality to be two times of the static one, which usually results in big errors. Here in this paper, based on the rotating field distribution, and using the integrated Bessel function, we deduced the cavity's storage and the rotating field dissipated power expressions, and obtained a modified cold quality formula for rotating TMn10 mode in the magnicon, which shows a good agreement with the experimental data.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Plenum Publishing Corporation, 1997</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Magnicon</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Rotating TMn10 Mode</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Cold Quality</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">International Journal of Infrared and Millimeter Waves</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">18/2(1997-02-01), 437-443</subfield>
   <subfield code="x">0195-9271</subfield>
   <subfield code="q">18:2&lt;437</subfield>
   <subfield code="1">1997</subfield>
   <subfield code="2">18</subfield>
   <subfield code="o">10762</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02677931</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02677931</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Zhang</subfield>
   <subfield code="D">HeBe</subfield>
   <subfield code="u">Institute of Applied Electronics, China Academy of Engineering Physics, P.O. Box 527, Postcode 610003, Chengdu, China</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">International Journal of Infrared and Millimeter Waves</subfield>
   <subfield code="d">Kluwer Academic Publishers-Plenum Publishers</subfield>
   <subfield code="g">18/2(1997-02-01), 437-443</subfield>
   <subfield code="x">0195-9271</subfield>
   <subfield code="q">18:2&lt;437</subfield>
   <subfield code="1">1997</subfield>
   <subfield code="2">18</subfield>
   <subfield code="o">10762</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="986" ind1=" " ind2=" ">
   <subfield code="a">SWISSBIB</subfield>
   <subfield code="b">477124402</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
