<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">477130968</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180405111704.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">170330e19970401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/BF02960650</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/BF02960650</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Experience in operating hydraulic structures and quipment of hydroelectric stations</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="b">Onstandard situations when performing starting and djustment works on the main and auxiliary quipment of hydroelectric stations</subfield>
   <subfield code="c">[G. Lokhmatikov, M. Mikhailov]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Conclusions: 1. The &quot;Guidelines on Starting, Adjusting, and Comprehensive Testing of Assembled Units” drawn up by the Union Institute for Planning and Organizing Power Construction (Orgénergostroi) in 1975 requires period updating onsideration of accumulated domestic and progressive foreign experience, comments, and suggestions of interested orgations and well as manufacturing plants. 2. The scheme of filling the water-delivery devices of the turbine should be specified by the design. 3. Accoording to the experience of starting and adjusting works, the best protection from unforeseen turnin otating parts of units is provided by pressing the braking jacks of the generator against the brake disk of the rotor by under a pressure of at least 50 kg/cm2 with fixing the brakes by lock nuts. The presence of anyone on rotating parts wit pressing the jacks by oil and locking the nuts should be categorically forbidden. Blowing out and converting the brake working from compressed air can be done immediately before starting the unit. 4. It is necessary to accumulate and systematize nonstandard situations when conducting starting and adjusting we including as an aid for training the appropriate personnel.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Plenum Publishing Corporation, 1997</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lokhmatikov</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Mikhailov</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Hydrotechnical Construction</subfield>
   <subfield code="d">Springer US</subfield>
   <subfield code="g">31/4(1997-04-01), 38-40</subfield>
   <subfield code="x">0018-8220</subfield>
   <subfield code="q">31:4&lt;38</subfield>
   <subfield code="1">1997</subfield>
   <subfield code="2">31</subfield>
   <subfield code="o">10749</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/BF02960650</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">brief-communication</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/BF02960650</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lokhmatikov</subfield>
   <subfield code="D">G.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Mikhailov</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Hydrotechnical Construction</subfield>
   <subfield code="d">Springer US</subfield>
   <subfield code="g">31/4(1997-04-01), 38-40</subfield>
   <subfield code="x">0018-8220</subfield>
   <subfield code="q">31:4&lt;38</subfield>
   <subfield code="1">1997</subfield>
   <subfield code="2">31</subfield>
   <subfield code="o">10749</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
