<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510731600</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411082955.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20130901xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s11708-013-0265-7</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s11708-013-0265-7</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Well-being analysis of GSU transformer insulation incorporating the impact on power generation using fuzzy logic</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Alagarsamy Krishnavel, Dusmata Mohanta, M. Reddy]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">With the prevailing power scenario, every watt-second of electrical energy has its own merit in satisfying the consumer demand. At the state of such a stringent energy demanding era, failure of a power generation equipment compounds the energy constraints which will not only result in a huge loss of generation but also have an impact on capital revenue. The unexpected failure of generator step-up (GSU) transformer is especially a major disturbance in the power system operation and leads to unscheduled outages with power delivery problems. The time lag in bringing back the equipment in service after rectification or replacement may increase the criticality as the process involves mobilization of spares and maintenance professionals. Hot atmosphere existing in the vicinity of thermal power stations running round-the-clock with more than 100% plant load factor (PLF) increases the thermal stress of the electrical insulation which leads to premature failure of windings, bushings, core laminations, etc. The healthy state of the GSU transformer has to be ensured to minimize the loss of power generation. As the predication related to failure of a GSU transformer is associated with some uncertainties, a fuzzy approach is employed in this paper along with actual field data and case studies for the well-being analysis of GSU transformer.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Higher Education Press and Springer-Verlag Berlin Heidelberg, 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">generator step-up (GSU) transformer</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">wellbeing analysis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">dissolved gases in oil analysis (DGA)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">tan delta (TD)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">sweep frequency response analysis (SFRA)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">fuzzy inference system (FIS)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Krishnavel</subfield>
   <subfield code="D">Alagarsamy</subfield>
   <subfield code="u">Department of Electrical and Electronics Engineering, Birla Institute of Technology, 835215, Mesra, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Mohanta</subfield>
   <subfield code="D">Dusmata</subfield>
   <subfield code="u">Department of Electrical and Electronics Engineering, Birla Institute of Technology, 835215, Mesra, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Reddy</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Department of Electrical and Electronics Engineering, National Institute of Technology, 620015, Tiruchirappalli, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Frontiers in Energy</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">7/3(2013-09-01), 288-299</subfield>
   <subfield code="x">2095-1701</subfield>
   <subfield code="q">7:3&lt;288</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">7</subfield>
   <subfield code="o">11708</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s11708-013-0265-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s11708-013-0265-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Krishnavel</subfield>
   <subfield code="D">Alagarsamy</subfield>
   <subfield code="u">Department of Electrical and Electronics Engineering, Birla Institute of Technology, 835215, Mesra, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Mohanta</subfield>
   <subfield code="D">Dusmata</subfield>
   <subfield code="u">Department of Electrical and Electronics Engineering, Birla Institute of Technology, 835215, Mesra, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Reddy</subfield>
   <subfield code="D">M.</subfield>
   <subfield code="u">Department of Electrical and Electronics Engineering, National Institute of Technology, 620015, Tiruchirappalli, India</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Frontiers in Energy</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">7/3(2013-09-01), 288-299</subfield>
   <subfield code="x">2095-1701</subfield>
   <subfield code="q">7:3&lt;288</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">7</subfield>
   <subfield code="o">11708</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
