<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510738354</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083019.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20130901xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s12127-013-0136-2</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s12127-013-0136-2</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Speciation effects of solvent chemistry on the analysis of drugs and explosives by electrospray ion mobility mass spectrometry</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Howard Holness, Jose Almirall]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The present work highlights the effect that solvent chemistry has on analytes being detected when utilizing electrospray ionization in ion mobility mass spectrometers. Various studies were conducted involving both positive and negative mode ionization. The enhancements observed by utilizing different levels of acid modifiers as well as the different ionic species of analytes being formed and detected are presented. The makeup of the electrospray solvent determined whether the ionic species would be protonated, sodium adducted, ammonium adducted, proton abstracted or chlorinated. Addition of solvent modifiers such as acids in the positive mode, and organic halides in the negative mode improved signal strength of analytes as well as improved spray characteristics that also decreased signal variability. The ability to perform simultaneous ionization of complex mixtures was also demonstrated through the use of solvent modifiers thereby allowing electrospray ionization ion mobility mass spectrometry the ability to simultaneously analyze complicated mixtures very quickly (millisecond separations).</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Berlin Heidelberg, 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Ion mobility</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Mass spectrometry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Electrospray</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Explosives</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Drugs</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Solvent chemistry</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Holness</subfield>
   <subfield code="D">Howard</subfield>
   <subfield code="u">Department of Chemistry and Biochemistry and International Forensic Research Institute, Florida International University, 11200 SW 8th Street, 33199, Miami, FL, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Almirall</subfield>
   <subfield code="D">Jose</subfield>
   <subfield code="u">Department of Chemistry and Biochemistry and International Forensic Research Institute, Florida International University, 11200 SW 8th Street, 33199, Miami, FL, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">International Journal for Ion Mobility Spectrometry</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">16/3(2013-09-01), 237-246</subfield>
   <subfield code="x">1435-6163</subfield>
   <subfield code="q">16:3&lt;237</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">16</subfield>
   <subfield code="o">12127</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s12127-013-0136-2</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s12127-013-0136-2</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Holness</subfield>
   <subfield code="D">Howard</subfield>
   <subfield code="u">Department of Chemistry and Biochemistry and International Forensic Research Institute, Florida International University, 11200 SW 8th Street, 33199, Miami, FL, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Almirall</subfield>
   <subfield code="D">Jose</subfield>
   <subfield code="u">Department of Chemistry and Biochemistry and International Forensic Research Institute, Florida International University, 11200 SW 8th Street, 33199, Miami, FL, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">International Journal for Ion Mobility Spectrometry</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">16/3(2013-09-01), 237-246</subfield>
   <subfield code="x">1435-6163</subfield>
   <subfield code="q">16:3&lt;237</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">16</subfield>
   <subfield code="o">12127</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
