<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510742505</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083033.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20130101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s12630-012-9809-2</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s12630-012-9809-2</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Real-time ultrasound-guided spinal anesthesia using the SonixGPS® needle tracking system: a case report</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Simon Wong, Ahtsham Niazi, Ki Chin, Vincent Chan]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">La rachianesthésie échoguidée en temps réel avec le système de suivi de l'aiguille SonixGPS®: une présentation de cas</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Purpose: The SonixGPS® is an electromagnetic needle tracking system for ultrasound-guided needle intervention. Both current and predicted needle tip position are displayed on the ultrasound screen in real-time, facilitating needle-beam alignment and guidance to the target. This case report illustrates the use of the SonixGPS system for successful performance of real-time ultrasound-guided spinal anesthesia in a patient with difficult spinal anatomy. Clinical features: A 67-yr-old male was admitted to our hospital to undergo revision of total right hip arthroplasty. His four previous arthroplasties for hip revision were performed under general anesthesia because he had undergone L3-L5 instrumentation for spinal stenosis. The L4-L5 interspace was viewed with the patient in the left lateral decubitus position. A 19G 80-mm proprietary needle (Ultrasonix Medical Corp, Richmond, BC, Canada) was inserted and directed through the paraspinal muscles to the ligamentum flavum in plane to the ultrasound beam. A 120-mm 25G Whitacre spinal needle was then inserted through the introducer needle in a conventional fashion. Successful dural puncture was achieved on the second attempt, as indicated by a flow of clear cerebrospinal fluid. The patient tolerated the procedure well, and the spinal anesthetic was adequate for the duration of the surgery. Conclusion: The SonixGPS is a novel technology that can reduce the technical difficulty of real-time ultrasound-guided neuraxial blockade. It may also have applications in other advanced ultrasound-guided regional anesthesia techniques where needle-beam alignment is critical.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Canadian Anesthesiologists' Society, 2012</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Wong</subfield>
   <subfield code="D">Simon</subfield>
   <subfield code="u">Department of Anesthesia, Toronto Western Hospital, 399 Bathurst Street, M5T 2S8, Toronto, ON, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Niazi</subfield>
   <subfield code="D">Ahtsham</subfield>
   <subfield code="u">Department of Anesthesia, Toronto Western Hospital, 399 Bathurst Street, M5T 2S8, Toronto, ON, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Chin</subfield>
   <subfield code="D">Ki</subfield>
   <subfield code="u">Department of Anesthesia, Toronto Western Hospital, 399 Bathurst Street, M5T 2S8, Toronto, ON, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Chan</subfield>
   <subfield code="D">Vincent</subfield>
   <subfield code="u">Department of Anesthesia, Toronto Western Hospital, 399 Bathurst Street, M5T 2S8, Toronto, ON, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Canadian Journal of Anesthesia/Journal canadien d'anesthésie</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">60/1(2013-01-01), 50-53</subfield>
   <subfield code="x">0832-610X</subfield>
   <subfield code="q">60:1&lt;50</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">12630</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s12630-012-9809-2</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s12630-012-9809-2</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Wong</subfield>
   <subfield code="D">Simon</subfield>
   <subfield code="u">Department of Anesthesia, Toronto Western Hospital, 399 Bathurst Street, M5T 2S8, Toronto, ON, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Niazi</subfield>
   <subfield code="D">Ahtsham</subfield>
   <subfield code="u">Department of Anesthesia, Toronto Western Hospital, 399 Bathurst Street, M5T 2S8, Toronto, ON, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Chin</subfield>
   <subfield code="D">Ki</subfield>
   <subfield code="u">Department of Anesthesia, Toronto Western Hospital, 399 Bathurst Street, M5T 2S8, Toronto, ON, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Chan</subfield>
   <subfield code="D">Vincent</subfield>
   <subfield code="u">Department of Anesthesia, Toronto Western Hospital, 399 Bathurst Street, M5T 2S8, Toronto, ON, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Canadian Journal of Anesthesia/Journal canadien d'anesthésie</subfield>
   <subfield code="d">Springer-Verlag</subfield>
   <subfield code="g">60/1(2013-01-01), 50-53</subfield>
   <subfield code="x">0832-610X</subfield>
   <subfield code="q">60:1&lt;50</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">12630</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
