<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">51074964X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083059.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20130901xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s11270-013-1656-4</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s11270-013-1656-4</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="2">
   <subfield code="a">A Full-Scale Successive Alkalinity-Producing Passive System (SAPPS) for the Treatment of Acid Mine Drainage</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Ju Lee, Jeehyeong Khim, Kwangje Woo, Won Ji]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The successive alkalinity-producing passive system (SAPPS) located in Gangneung, South Korea was designed to treat acid mine drainage. The performance of SAPPS has been monitored intensively for 3years at the component level (influent, settling pond A, the successive alkalinity-producing system (SAPS), settling pond B, constructed wetland, and effluent). This study evaluated the ability of SAPPS to remove acidity and iron from influents at flow rates ranging from 17 to 160m3/day. The concentration of soluble Fetotal was the highest, and the pH was the lowest at low flow rates (≤61m3/day). When flow rates were over 80m3/day, concentrations decreased and Fetotal was removed primarily at the SAPS stage. For flow rates of less than 61m3/day, Fetotal was removed at the SAPS stage as well as in settling pond B and at the constructed wetland. Hydraulic retention times of 1 and 2days were found to be appropriate and economical for use with the SAPS stage and for settling pond B and the constructed wetland, respectively The treatment of acid mine drainage by conventional SAPPSs is limited by the availability of alkaline materials. However, the new proposed system can address this weakness through the provisioning of a suitable alkalinity supply.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Science+Business Media Dordrecht, 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Successive alkalinity-producing passive system (SAPPS)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">SAPS</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Fetotal</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Acid mine drainage (AMD)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Alkalinity supply system</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lee</subfield>
   <subfield code="D">Ju</subfield>
   <subfield code="u">Department of Civil and Environmental Engineering, Seoul National University and Korea Institute of Science and Technology (KIST), 151-742, Seoul, South Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Khim</subfield>
   <subfield code="D">Jeehyeong</subfield>
   <subfield code="u">School of Civil, Environmental and Architectural Engineering, Korea University, 136-701, Seoul, South Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Woo</subfield>
   <subfield code="D">Kwangje</subfield>
   <subfield code="u">School of Civil, Environmental and Architectural Engineering, Korea University, 136-701, Seoul, South Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ji</subfield>
   <subfield code="D">Won</subfield>
   <subfield code="u">Department of Water and Ecological Restoration, Mine Reclamation Corporation, 151-742, Seoul, South Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Water, Air, &amp; Soil Pollution</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">224/9(2013-09-01), 1-8</subfield>
   <subfield code="x">0049-6979</subfield>
   <subfield code="q">224:9&lt;1</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">224</subfield>
   <subfield code="o">11270</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s11270-013-1656-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s11270-013-1656-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lee</subfield>
   <subfield code="D">Ju</subfield>
   <subfield code="u">Department of Civil and Environmental Engineering, Seoul National University and Korea Institute of Science and Technology (KIST), 151-742, Seoul, South Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Khim</subfield>
   <subfield code="D">Jeehyeong</subfield>
   <subfield code="u">School of Civil, Environmental and Architectural Engineering, Korea University, 136-701, Seoul, South Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Woo</subfield>
   <subfield code="D">Kwangje</subfield>
   <subfield code="u">School of Civil, Environmental and Architectural Engineering, Korea University, 136-701, Seoul, South Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ji</subfield>
   <subfield code="D">Won</subfield>
   <subfield code="u">Department of Water and Ecological Restoration, Mine Reclamation Corporation, 151-742, Seoul, South Korea</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Water, Air, &amp; Soil Pollution</subfield>
   <subfield code="d">Springer Netherlands</subfield>
   <subfield code="g">224/9(2013-09-01), 1-8</subfield>
   <subfield code="x">0049-6979</subfield>
   <subfield code="q">224:9&lt;1</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">224</subfield>
   <subfield code="o">11270</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
