<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510757936</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083129.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20131201xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s11428-013-1121-4</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s11428-013-1121-4</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Kontinuierliche Glucosemessung bei erwachsenen Typ-I-Diabetes-Patienten</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[L. Heinemann, T. Siegmund]</subfield>
  </datafield>
  <datafield tag="246" ind1="1" ind2=" ">
   <subfield code="a">Continuous glucose monitoring in adult patients with type 1 diabetes</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Die Möglichkeit des kontinuierlichen Glucose-Monitorings (&quot;continuous glucose monitoring&quot;, CGM) stellt einen der wesentlichen Therapiefortschritte in den vergangenen 15Jahren dar. Sie kann für diagnostische Zwecke (über Tage bis Wochen) oder für die dauerhafte Behandlung eingesetzt werden. Auch die klinische Entscheidungsfindung wird vom CGM-System unterstützt, denn dieses gibt nicht nur die momentane Glucosekonzentration wieder, sondern ebenfalls den Trend und das Glucoseprofil während einiger Stunden vor der jeweiligen Messung. Die Verwendung von CGM in Kombination mit der kontinuierlichen subkutanen Insulininfusion (&quot;continuous subcutaneous insulin infusion&quot;, CSII) ermöglicht die sensorgestützte Insulinpumpentherapie und die automatische Abschaltung der Insulininfusion, wenn der Patient bei niedrigen Glucosekonzentrationen nicht reagiert (&quot;low-glucose suspend&quot;, LGS). Mit CGM lassen sich also die Stoffwechselkontrolle optimieren, die Ziel-HbA1c-Konzentrationen einhalten und gleichzeitig das Risiko für hypoglykämische Ereignisse verringern.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Berlin Heidelberg, 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Diabetes mellitus TypI</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Insulininfusionssysteme</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Kontinuierliche Glucosemonitoring</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Blutglucose-Selbstmessung</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">&quot;Closed loop&quot;</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Type 1 diabetes mellitus</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Insulin infusion systems</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Continuous glucose monitoring</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Blood glucose self-monitoring</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Closed loop</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">AGDT : Arbeitsgemeinschaft Diabetologische Technologie</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">CGM : &quot;continuous glucose monitoring&quot;</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">CSII : &quot;continuous subcutaneous insulin infusion&quot;</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">FDA : Food and Drug Administration</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">LGS : &quot;low-glucose suspend&quot;</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">MAD : &quot;mean absolute difference&quot;</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">PLGS : &quot;predictive low-glucose suspend&quot;</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">SMBG : Selbstmessung der kapillären Plasmaglucosekonzentration</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">SuP : sensorunterstützte Pumpentherapie</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Heinemann</subfield>
   <subfield code="D">L.</subfield>
   <subfield code="u">Science &amp; Co., Kehler Str. 24, 40468, Düsseldorf, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Siegmund</subfield>
   <subfield code="D">T.</subfield>
   <subfield code="u">Städt. Klinikum München GmbH, Klinikum Bogenhausen, München, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s11428-013-1121-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s11428-013-1121-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Heinemann</subfield>
   <subfield code="D">L.</subfield>
   <subfield code="u">Science &amp; Co., Kehler Str. 24, 40468, Düsseldorf, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Siegmund</subfield>
   <subfield code="D">T.</subfield>
   <subfield code="u">Städt. Klinikum München GmbH, Klinikum Bogenhausen, München, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>