  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Failure of the crossover pipes used in the PK-39-IIM boiler middle radiant part and a numerical analysis of the factors caused this failure</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[V. Baranov, A. Gorb, S. Nikolaev]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The consequences resulting from an emergency failure of one subflow in the middle radiant part of a modernized PK-39-IIM boiler occurred during one of its first startups after the erection are presented. A numerical analysis of the factors that caused this failure is carried out. The calculation was carried out in accordance with the recommendations suggested in the standard method of hydraulic design. It is shown that at a load equal to 40% of its nominal value, increment of heat absorption in the subflow equal to 586 kJ/kg (140 kcal/kg), and heat absorption nonuniformity coefficient in the misaligned element equal to 1.5, the temperature of medium downstream of the subflow is equal to 670°C (operating conditions close to those under which the failure occurred).</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Pleiades Publishing, Ltd., 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">boiler</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">steam-water path</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">half-flow</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">temperature</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">enthalpy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">heat absorption</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Baranov</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">Sibtekhenergo, Planirovochnaya ul. 18/1, 630032, Novosibirsk, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Gorb</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Sibtekhenergo, Planirovochnaya ul. 18/1, 630032, Novosibirsk, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Nikolaev</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Sibtekhenergo, Planirovochnaya ul. 18/1, 630032, Novosibirsk, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Thermal Engineering</subfield>
   <subfield code="d">SP MAIK Nauka/Interperiodica</subfield>
   <subfield code="g">60/6(2013-06-01), 409-412</subfield>
   <subfield code="x">0040-6015</subfield>
   <subfield code="q">60:6&lt;409</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">11509</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1134/S0040601513060025</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1134/S0040601513060025</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Baranov</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">Sibtekhenergo, Planirovochnaya ul. 18/1, 630032, Novosibirsk, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Gorb</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Sibtekhenergo, Planirovochnaya ul. 18/1, 630032, Novosibirsk, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Nikolaev</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Sibtekhenergo, Planirovochnaya ul. 18/1, 630032, Novosibirsk, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Thermal Engineering</subfield>
   <subfield code="d">SP MAIK Nauka/Interperiodica</subfield>
   <subfield code="g">60/6(2013-06-01), 409-412</subfield>
   <subfield code="x">0040-6015</subfield>
   <subfield code="q">60:6&lt;409</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">11509</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>