<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510761194</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083140.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20130601xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1134/S0040601513060013</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1134/S0040601513060013</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="2">
   <subfield code="a">A prospect for achieving more efficient combustion of Kuznetsk lean coal in a boiler with dry-ash removal</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[A. Arkhipov, A. Roor]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A new high-efficient technology for staged combustion of Kuznetsk lean coal in PK-10 boilers with dry-ash removal is proposed, which involves the use of direct-flow burners, secondary-air nozzles, and combined nozzles, all installed on the furnace lateral walls. It is expected that more reliable, economically efficient, and environmentally friendly operation of the boilers will be achieved after putting the new technology into operation.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Pleiades Publishing, Ltd., 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">staged combustion</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">lean coal</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">dry-ash removal</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">direct-flow burners</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">nozzles</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">reliability</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">economic efficiency</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">environmental friendliness</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">boilers</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Arkhipov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Moscow Power Engineering Institute, Krasnokazarmennaya ul. 14, 111250, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Roor</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">South Kuzbass Power Company, ul. Mira 30a, 652990, Tashtagol, Kemerovo oblast, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Thermal Engineering</subfield>
   <subfield code="d">SP MAIK Nauka/Interperiodica</subfield>
   <subfield code="g">60/6(2013-06-01), 397-401</subfield>
   <subfield code="x">0040-6015</subfield>
   <subfield code="q">60:6&lt;397</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">11509</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1134/S0040601513060013</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1134/S0040601513060013</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Arkhipov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Moscow Power Engineering Institute, Krasnokazarmennaya ul. 14, 111250, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Roor</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">South Kuzbass Power Company, ul. Mira 30a, 652990, Tashtagol, Kemerovo oblast, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Thermal Engineering</subfield>
   <subfield code="d">SP MAIK Nauka/Interperiodica</subfield>
   <subfield code="g">60/6(2013-06-01), 397-401</subfield>
   <subfield code="x">0040-6015</subfield>
   <subfield code="q">60:6&lt;397</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">11509</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
