<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510761402</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083140.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20130701xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1134/S0040601513070100</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1134/S0040601513070100</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Problems and prospects connected with development of high-temperature filtration technology at nuclear power plants equipped with VVER-1000 reactors</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[S. Shchelik, A. Pavlov]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Results of work on restoring the service properties of filtering material used in the high-temperature reactor coolant purification system of a VVER-1000 reactor are presented. A quantitative assessment is given to the effect from subjecting a high-temperature sorbent to backwashing operations carried out with the use of regular capacities available in the design process circuit in the first years of operation of Unit 3 at the Kalinin nuclear power plant. Approaches to optimizing this process are suggested. A conceptual idea about comprehensively solving the problem of achieving more efficient and safe operation of the high-temperature active water treatment system (AWT-1) on a nuclear power industry-wide scale is outlined.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Pleiades Publishing, Ltd., 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">AWT-1</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">high-temperature sorbent</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">high-temperature purification</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Kalinin nuclear power plant</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Shchelik</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Kalininatomtekhenergo, Tverskaya ul. 5, 171841, Udomlya, Tver oblast, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Pavlov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Kalinin Nuclear Power Plant, ul. Popova 25, 171841, Udomlya, Tver oblast, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Thermal Engineering</subfield>
   <subfield code="d">SP MAIK Nauka/Interperiodica</subfield>
   <subfield code="g">60/7(2013-07-01), 477-481</subfield>
   <subfield code="x">0040-6015</subfield>
   <subfield code="q">60:7&lt;477</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">11509</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1134/S0040601513070100</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1134/S0040601513070100</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Shchelik</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">Kalininatomtekhenergo, Tverskaya ul. 5, 171841, Udomlya, Tver oblast, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Pavlov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Kalinin Nuclear Power Plant, ul. Popova 25, 171841, Udomlya, Tver oblast, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Thermal Engineering</subfield>
   <subfield code="d">SP MAIK Nauka/Interperiodica</subfield>
   <subfield code="g">60/7(2013-07-01), 477-481</subfield>
   <subfield code="x">0040-6015</subfield>
   <subfield code="q">60:7&lt;477</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">11509</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
