<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510761755</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083142.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20131001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1134/S0040601513100017</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1134/S0040601513100017</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Field experience gained from the use of microprocessor automated process control systems for large modernized power units</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[V. Bilenko, L. Grekhov, A. Sviderskii, A. Strukov]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">We describe the results obtained from long-term operation of 11 large power units at eight power stations after their previous traditional monitoring and control systems had been modernized with the use of Teleperm XP-R (TPTS-51 and OM-650) computerized automation system. The modernized automated process control systems were analyzed on the basis of a special questionnaire in which various aspects of estimating the modernization results were addressed: from adequacy of the adopted fundamental solutions to problems encountered during operation of the installed computerized automation systems. Experience gained from operation of the hardware used in the controller and upper control levels and from operation of application software, including process protections, automatic closed-loop control systems, step control programs, video frame subsystems, and calculation tasks. Appraisals given to the above-mentioned problems by power station specialists are analyzed.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Pleiades Publishing, Ltd., 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">modernization of automated process control systems</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">experience gained from operation of the TPTS-51 and OM-650 systems</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">coal-fired and gas-and-oil-fired power units</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">microprocessor automation systems</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">reliability of technical facilities</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">emergency shutdown control desk</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">power unit closed-loop automatic control systems</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">step control programs</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">control of frequency and power</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Bilenko</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">Interavtomatika, Avtozavodskaya ul. 14, 115280, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Grekhov</subfield>
   <subfield code="D">L.</subfield>
   <subfield code="u">Interavtomatika, Avtozavodskaya ul. 14, 115280, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Sviderskii</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Interavtomatika, Avtozavodskaya ul. 14, 115280, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Strukov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Interavtomatika, Avtozavodskaya ul. 14, 115280, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Thermal Engineering</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">60/10(2013-10-01), 703-713</subfield>
   <subfield code="x">0040-6015</subfield>
   <subfield code="q">60:10&lt;703</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">11509</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1134/S0040601513100017</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1134/S0040601513100017</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Bilenko</subfield>
   <subfield code="D">V.</subfield>
   <subfield code="u">Interavtomatika, Avtozavodskaya ul. 14, 115280, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Grekhov</subfield>
   <subfield code="D">L.</subfield>
   <subfield code="u">Interavtomatika, Avtozavodskaya ul. 14, 115280, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Sviderskii</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Interavtomatika, Avtozavodskaya ul. 14, 115280, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Strukov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">Interavtomatika, Avtozavodskaya ul. 14, 115280, Moscow, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Thermal Engineering</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">60/10(2013-10-01), 703-713</subfield>
   <subfield code="x">0040-6015</subfield>
   <subfield code="q">60:10&lt;703</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">60</subfield>
   <subfield code="o">11509</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
