<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510766293</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083157.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20131001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s11630-013-0645-7</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s11630-013-0645-7</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Influence of diffuser on aerodynamic noise of a forward curved fan</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Soichi Sasaki, Kota Suzuki, Yuta Onomichi, Hidechito Hayashi]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">In order to clarify the influence of a diffuser on the characteristics of a forward curved fan, the influence of the bare ratio and the outlet angle on the characteristics of the fan were measured through an experiment performed with an actual fan as well as through a numerical simulation, respectively. The mechanism of the discrete frequency noise generated by the separated flow of the diffuser was analyzed. The optimized bare ratio was approximately 17%. The flow separated inside of the diffuser generated discrete frequency noise owing to the interaction between the reversed flow from the diffuser and the impeller rotating at the blade passing frequency. The diffuser outlet angle influenced the pressure ratio more than that by the bare ratio. Furthermore, it was confirmed that restraining the separation in the diffuser effectively decreases the fan noise.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Science Press, Institute of Engineering Thermophysics, CAS and Springer-Verlag Berlin Heidelberg, 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Pressure Drop</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Fan</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Aerodynamic Noise</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Internal Flow</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Separation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Sasaki</subfield>
   <subfield code="D">Soichi</subfield>
   <subfield code="u">Division of System Science, Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, 852-8521, Nagasaki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Suzuki</subfield>
   <subfield code="D">Kota</subfield>
   <subfield code="u">Department of Advanced Engineering, Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, 852-8521, Nagasaki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Onomichi</subfield>
   <subfield code="D">Yuta</subfield>
   <subfield code="u">Department of Advanced Engineering, Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, 852-8521, Nagasaki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hayashi</subfield>
   <subfield code="D">Hidechito</subfield>
   <subfield code="u">Division of System Science, Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, 852-8521, Nagasaki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Thermal Science</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">22/5(2013-10-01), 433-438</subfield>
   <subfield code="x">1003-2169</subfield>
   <subfield code="q">22:5&lt;433</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">22</subfield>
   <subfield code="o">11630</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s11630-013-0645-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s11630-013-0645-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Sasaki</subfield>
   <subfield code="D">Soichi</subfield>
   <subfield code="u">Division of System Science, Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, 852-8521, Nagasaki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Suzuki</subfield>
   <subfield code="D">Kota</subfield>
   <subfield code="u">Department of Advanced Engineering, Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, 852-8521, Nagasaki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Onomichi</subfield>
   <subfield code="D">Yuta</subfield>
   <subfield code="u">Department of Advanced Engineering, Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, 852-8521, Nagasaki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hayashi</subfield>
   <subfield code="D">Hidechito</subfield>
   <subfield code="u">Division of System Science, Graduate School of Engineering, Nagasaki University, 1-14 Bunkyo-machi, 852-8521, Nagasaki, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Thermal Science</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">22/5(2013-10-01), 433-438</subfield>
   <subfield code="x">1003-2169</subfield>
   <subfield code="q">22:5&lt;433</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">22</subfield>
   <subfield code="o">11630</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
