<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510770231</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083211.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20130901xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s11837-013-0700-6</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s11837-013-0700-6</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Suzuki</subfield>
   <subfield code="D">Seiichi</subfield>
   <subfield code="u">TSL Solutions KK, #SIC2-401, 5-4-30, Nishihashimoto, Midori-Ku, 252-0131, Kanagawa, Sagamihara, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Features of Transmission EBSD and its Application</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Seiichi Suzuki]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Features of transmission electron backscatter diffraction (EBSD) observation with a standard EBSD (s-EBSD) detector are surveyed in this study. Heavily deformed Al and 8Cr tempered martensite transmission electron microscope (TEM) specimens were used for this study. It is shown that a specimen tilt angle of ~30°-40° in the opposite direction of the usual 70° and a smaller working distance in the range 4mm-5mm are recommended when using a s-EBSD detector. Specimen thickness and accelerating voltage (Acc.V) have a strong affect on the quality of transmission EBSD patterns and orientation maps. Higher Acc.Vs are generally recommended to get good quality orientation maps. In case of very thin specimens, lowering the Acc.Vs will give better results. In the observation of a thin film of an 8Cr tempered martensite steel specimen, it is confirmed that t-EBSD can provide images and detailed quantitative orientation data comparable with that obtained by TEM. It is also shown that small precipitates of Cr23C6 with sizes around 30nm could be detected and their orientations measured.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">The Author(s), 2013</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">JOM</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">65/9(2013-09-01), 1254-1263</subfield>
   <subfield code="x">1047-4838</subfield>
   <subfield code="q">65:9&lt;1254</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">65</subfield>
   <subfield code="o">11837</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s11837-013-0700-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s11837-013-0700-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Suzuki</subfield>
   <subfield code="D">Seiichi</subfield>
   <subfield code="u">TSL Solutions KK, #SIC2-401, 5-4-30, Nishihashimoto, Midori-Ku, 252-0131, Kanagawa, Sagamihara, Japan</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">JOM</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">65/9(2013-09-01), 1254-1263</subfield>
   <subfield code="x">1047-4838</subfield>
   <subfield code="q">65:9&lt;1254</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">65</subfield>
   <subfield code="o">11837</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
