<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510777813</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083236.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20130901xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s11678-013-0218-0</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s11678-013-0218-0</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Ketterl</subfield>
   <subfield code="D">Rupert</subfield>
   <subfield code="u">Klinikum Traunstein, Unfallchirurgie und Orthopädische Chirurgie, Schwerpunkt Hand- und Wirbelsäulenchirurgie,, Cuno-Niggl-Str. 3, 83278, Traunstein, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Wird das Outcome durch den Einsatz einer minimalinvasiven Operationstechnik mit winkelstabiler Plattenosteosynthese bei proximalen Humerusfrakturen verbessert?</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Rupert Ketterl]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">Can the outcome of proximal humeral fractures be improved using a minimally invasive surgical technique for fixed-angle plate osteosynthesis?</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Fragestellung: Kann durch die Änderung der Operationstechnik mit Einbringung einer winkelstabilen Platte über einen minimalinvasiven Zugang unter Zuhilfenahme eines Zielbügels eine Verbesserung der Behandlungsergebnisse erzielt werden? Methodik: Bei 100Patienten, die bei Humeruskopffrakturen mit winkelstabiler Plattenosteosynthese unter Zuhilfenahme eines Zielbügels über einen Deltoidsplit-Zugang versorgt wurden, erfolgte über einen Zeitraum von 3Jahren prospektiv eine Datenerhebung. Die Ergebnisse wurden mit einer Gruppe von 100Patienten verglichen, die bei Humeruskopffrakturen mit demselben Implantat, jedoch in offener Operationstechnik über einen deltoideopektoralen Zugang osteosynthetisch versorgt wurden. Diese Daten wurden ebenfalls prospektiv über einen Zeitraum von 3Jahren gewonnen. Ergebnisse: Mit Einführung der minimalinvasiven Operationstechnik konnte die Operationszeit und die stationäre Aufenthaltsdauer signifikant verkürzt werden. Erzielt wurde eine Reduktion der Schmerzempfindung und Komplikationsrate, eine Verbesserung der Beweglichkeit und des funktionellen Outcomes. Die Ergebnisse zeigten sich früh postoperativ sowie in den ersten Monaten signifikant. Zu einem späteren Zeitpunkt waren die Unterschiede noch nachweisbar, jedoch nicht mehr in der ursprünglichen Ausprägung vorhanden. Schlussfolgerung: Die Plattenosteosynthese hat bei der Versorgung von proximalen Humerusfrakturen weiterhin ihren Stellenwert. Durch eine minimalinvasive Operationstechnik lassen sich die frühzeitigen Behandlungsergebnisse bei Versorgung von proximalen Humerusfrakturen mittels Plattenosteosynthese verbessern. Die in der perioperativen Phase und in den ersten Monaten signifikanten Vorteile lassen sich im Langzeitverlauf nicht mehr in der ursprünglichen Ausprägung nachweisen.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Berlin Heidelberg, 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Proximale Humerusfrakturen</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Winkelstabile Plattenosteosynthese</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Minimalinvasive Technik</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Proximal humeral fractures</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Fixed-angle plate osteosynthesis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Minimally invasive technique</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Obere Extremität</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">8/3(2013-09-01), 157-163</subfield>
   <subfield code="x">1862-6599</subfield>
   <subfield code="q">8:3&lt;157</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">8</subfield>
   <subfield code="o">11678</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s11678-013-0218-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s11678-013-0218-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ketterl</subfield>
   <subfield code="D">Rupert</subfield>
   <subfield code="u">Klinikum Traunstein, Unfallchirurgie und Orthopädische Chirurgie, Schwerpunkt Hand- und Wirbelsäulenchirurgie,, Cuno-Niggl-Str. 3, 83278, Traunstein, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Obere Extremität</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">8/3(2013-09-01), 157-163</subfield>
   <subfield code="x">1862-6599</subfield>
   <subfield code="q">8:3&lt;157</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">8</subfield>
   <subfield code="o">11678</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
