<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510807232</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083424.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20131101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s11548-013-0897-4</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s11548-013-0897-4</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Projection-based visual guidance for robot-aided RF needle insertion</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Rong Wen, Chee-Kong Chui, Sim-Heng Ong, Kah-Bin Lim, Stephen Chang]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Purpose: The use of projector-based augmented reality (AR) in surgery may enable surgeons to directly view anatomical models and surgical data from the patient's surface (skin). It has the advantages of a consistent viewing focus on the patient, an extended field of view and augmented interaction. This paper presents an AR guidance mechanism with a projector-camera system to provide the surgeon with direct visual feedback for supervision of robotic needle insertion in radiofrequency (RF) ablation treatment. Methods: The registration of target organ models to specific positions on the patient body is performed using a surface-matching algorithm and point-based registration. An algorithm based on the extended Kalman filter and spatial transformation is used to intraoperatively compute the virtual needle's depth in the patient's body for AR display. Results: Experiments of this AR system on a mannequin were conducted to evaluate AR visualization and accuracy of virtual RF needle insertion. The average accuracy of 1.86mm for virtual needle insertion met the clinical requirement of 2mm or better. The feasibility of augmented interaction with a surgical robot using the proposed open AR interface with active visual feedback was demonstrated. Conclusions: The experimental results demonstrate that this guidance system is effective in assisting a surgeon to perform a robot-assisted radiofrequency ablation procedure. The novelty of the work lies in establishing a navigational procedure for percutaneous surgical augmented intervention integrating a projection-based AR guidance and robotic implementation for surgical needle insertion.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">CARS, 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Augmented reality</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Augmented interaction</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Visual guidance</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Image-guided surgery</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Projector-camera system</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Radiofrequency ablation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Wen</subfield>
   <subfield code="D">Rong</subfield>
   <subfield code="u">Department of Mechanical Engineering, National University of Singapore, 117576, Singapore, Singapore</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Chui</subfield>
   <subfield code="D">Chee-Kong</subfield>
   <subfield code="u">Department of Mechanical Engineering, National University of Singapore, 117576, Singapore, Singapore</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Ong</subfield>
   <subfield code="D">Sim-Heng</subfield>
   <subfield code="u">Department of Electrical and Computer Engineering, National University of Singapore, 117576, Singapore, Singapore</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lim</subfield>
   <subfield code="D">Kah-Bin</subfield>
   <subfield code="u">Department of Mechanical Engineering, National University of Singapore, 117576, Singapore, Singapore</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Chang</subfield>
   <subfield code="D">Stephen</subfield>
   <subfield code="u">Department of Surgery, National University Hospital, 119077, Singapore, Singapore</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">International Journal of Computer Assisted Radiology and Surgery</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">8/6(2013-11-01), 1015-1025</subfield>
   <subfield code="x">1861-6410</subfield>
   <subfield code="q">8:6&lt;1015</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">8</subfield>
   <subfield code="o">11548</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s11548-013-0897-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s11548-013-0897-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Wen</subfield>
   <subfield code="D">Rong</subfield>
   <subfield code="u">Department of Mechanical Engineering, National University of Singapore, 117576, Singapore, Singapore</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Chui</subfield>
   <subfield code="D">Chee-Kong</subfield>
   <subfield code="u">Department of Mechanical Engineering, National University of Singapore, 117576, Singapore, Singapore</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Ong</subfield>
   <subfield code="D">Sim-Heng</subfield>
   <subfield code="u">Department of Electrical and Computer Engineering, National University of Singapore, 117576, Singapore, Singapore</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lim</subfield>
   <subfield code="D">Kah-Bin</subfield>
   <subfield code="u">Department of Mechanical Engineering, National University of Singapore, 117576, Singapore, Singapore</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Chang</subfield>
   <subfield code="D">Stephen</subfield>
   <subfield code="u">Department of Surgery, National University Hospital, 119077, Singapore, Singapore</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">International Journal of Computer Assisted Radiology and Surgery</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">8/6(2013-11-01), 1015-1025</subfield>
   <subfield code="x">1861-6410</subfield>
   <subfield code="q">8:6&lt;1015</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">8</subfield>
   <subfield code="o">11548</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
