<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     naa a22        4500</leader>
  <controlfield tag="001">510810101</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20180411083438.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">180411e20130901xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1134/S1064230713040059</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1134/S1064230713040059</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Robust control of electric generator in the case of time-dependent mechanical power</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[A. Belyaev, S. Smolovik, A. Fradkov, I. Furtat]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The problem of control of electric generator whose model is described by a third-order differential algebraic equation with a priori unknown parameters under uncontrollable external disturbance defined by an unknown time-dependent power is solved. When the problem is solved, it is assumed that the relative speed of the generator's rotor can be measured. A control algorithm ensuring small amplitude of the rotor vibrations in the quasi-steady-state mode due to changes in the voltage at the excitation coil of the rotor is proposed. This algorithm also ensures the stable operation under emergency conditions caused by changes in the reactive resistance of the power transmission line. Numerical examples and the results of computer simulation are presented to illustrate the performance of the proposed control algorithm.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Pleiades Publishing, Ltd., 2013</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Belyaev</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">High Voltage Direct Current Power Transmission Research Institute, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Smolovik</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">High Voltage Direct Current Power Transmission Research Institute, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Fradkov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">High Voltage Direct Current Power Transmission Research Institute, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Furtat</subfield>
   <subfield code="D">I.</subfield>
   <subfield code="u">High Voltage Direct Current Power Transmission Research Institute, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Journal of Computer and Systems Sciences International</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">52/5(2013-09-01), 750-758</subfield>
   <subfield code="x">1064-2307</subfield>
   <subfield code="q">52:5&lt;750</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">52</subfield>
   <subfield code="o">11488</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1134/S1064230713040059</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1134/S1064230713040059</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Belyaev</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">High Voltage Direct Current Power Transmission Research Institute, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Smolovik</subfield>
   <subfield code="D">S.</subfield>
   <subfield code="u">High Voltage Direct Current Power Transmission Research Institute, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Fradkov</subfield>
   <subfield code="D">A.</subfield>
   <subfield code="u">High Voltage Direct Current Power Transmission Research Institute, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Furtat</subfield>
   <subfield code="D">I.</subfield>
   <subfield code="u">High Voltage Direct Current Power Transmission Research Institute, St. Petersburg, Russia</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Journal of Computer and Systems Sciences International</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">52/5(2013-09-01), 750-758</subfield>
   <subfield code="x">1064-2307</subfield>
   <subfield code="q">52:5&lt;750</subfield>
   <subfield code="1">2013</subfield>
   <subfield code="2">52</subfield>
   <subfield code="o">11488</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
 </record>
</collection>
