<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605450250</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100146.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20150801xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00347-015-0106-7</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00347-015-0106-7</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Hoffmann</subfield>
   <subfield code="D">E.M.</subfield>
   <subfield code="u">Augenklinik und Poliklinik, Universitätsmedizin Mainz, Langenbeckstr. 1, 55131, Mainz, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Stellenwert der Heidelberg-Retina-Tomographie in der Glaukomdiagnostik</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[E.M. Hoffmann]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">Value of Heidelberg retinal tomography in glaucoma diagnostics</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Hintergrund: Die Heidelberg-Retina-Tomographie (HRT) hat sich sowohl als Frühdiagnoseverfahren als auch für die Verlaufskontrolle des Glaukoms etabliert. Seit mehr als 2Jahrzehnten wird dieses Verfahren nun in der Glaukomdiagnostik erfolgreich verwendet. Die Hardware und Software wurde entsprechend den aktuellen Erfordernissen und Weiterentwicklungen angepasst. Viele Hunderte von wissenschaftlichen Untersuchungen haben die Zuverlässigkeit und Genauigkeit der HRT für die Frühdiagnose der Glaukomerkrankung untersucht. Ebenso viele Studien finden sich zur Detektion von Progression bei Glaukom. Die Verlaufskontrolle ist weiterhin eine unumfochtene Stärke des Verfahrens, und die zugrunde liegenden statistischen Analysen wurden in den letzten Jahren von renommierten Wissenschaftlern permanent verbessert und optimiert. Methoden: Neben der Änderung der stereometrischen Parameter und der Trendanalyse kann vor allem die Topographic-Change-Analyse (TCA) für die Verlaufskontrolle verwendet werden. Auch der Flickervergleich ist eine sehr wertvolle Methode, um topographische Änderungen im Vergleich zur Basisuntersuchung zu evaluieren. Zusammenfassung: Die HRT als Diagnoseverfahren wird somit auch in Zukunft einen hohen Stellenwert einnehmen mit einem besonderen Fokus auf der Progressionsbeurteilung.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Berlin Heidelberg, 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Glaukomfrüherkennung</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Progression</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Verlaufsbeobachtung</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Flickervergleich</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Topographic-Change-Analyse</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Course observation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Flicker comparison</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Topographic change analysis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Glaucoma early detection</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00347-015-0106-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00347-015-0106-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hoffmann</subfield>
   <subfield code="D">E.M.</subfield>
   <subfield code="u">Augenklinik und Poliklinik, Universitätsmedizin Mainz, Langenbeckstr. 1, 55131, Mainz, Deutschland</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
 </record>
</collection>
