<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605456127</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100216.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20150101xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00167-013-2421-3</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00167-013-2421-3</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Abdelkafy</subfield>
   <subfield code="D">Ashraf</subfield>
   <subfield code="u">Orthopaedic Surgery and Traumatology Department, Faculty of Medicine, Suez Canal University, Circular Road, 41522, Ismailia, Egypt</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="4">
   <subfield code="a">The concept of three-dimensional hold of both circumferential and radial collagen fibres of the meniscus</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Ashraf Abdelkafy]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Collagen fibres of the meniscus arrange into two main orientations: circumferential fibres parallel to the long axis of the meniscus and radial fibres perpendicular to the long axis of the meniscus. Meniscal sutures are placed either in vertical or in horizontal orientations. Vertical sutures better hold circumferential fibres because it encircles them like a rope holding a bunch of tree branches. In the same manner, horizontal sutures better hold radial fibres. The &quot;Simplified Cruciate Suture” consists of two vertical oblique sutures. Placing two vertical sutures in an oblique orientation captures greater meniscal tissue volume, holds and grasps both circumferential and radial collagen fibres of the meniscus into a three-dimensional plane with eventual high fixation strength of the repaired meniscal tear. Simplified cruciate suture is indicated for the repair of long bucket handle tears where it is placed in the middle of the tear like an anchor, and additional vertical and horizontal sutures are placed anterior and posterior to it as needed. Level of evidence V.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Berlin Heidelberg, 2013</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Arthroscopic mensical repair</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Simplified cruciate suture</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Ultimate tension load</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Circumferential collagen fibres</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Radial collagen fibres</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Collagen fibres</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Knee Surgery, Sports Traumatology, Arthroscopy</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">23/1(2015-01-01), 20-25</subfield>
   <subfield code="x">0942-2056</subfield>
   <subfield code="q">23:1&lt;20</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">23</subfield>
   <subfield code="o">167</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00167-013-2421-3</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">brief-communication</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00167-013-2421-3</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Abdelkafy</subfield>
   <subfield code="D">Ashraf</subfield>
   <subfield code="u">Orthopaedic Surgery and Traumatology Department, Faculty of Medicine, Suez Canal University, Circular Road, 41522, Ismailia, Egypt</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Knee Surgery, Sports Traumatology, Arthroscopy</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">23/1(2015-01-01), 20-25</subfield>
   <subfield code="x">0942-2056</subfield>
   <subfield code="q">23:1&lt;20</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">23</subfield>
   <subfield code="o">167</subfield>
  </datafield>
 </record>
</collection>
