Improved positioning of the tibial component in unicompartmental knee arthroplasty with patient-specific cutting blocks
Gespeichert in:
Verfasser / Beitragende:
[M. Dao Trong, C. Diezi, G. Goerres, N. Helmy]
Ort, Verlag, Jahr:
2015
Enthalten in:
Knee Surgery, Sports Traumatology, Arthroscopy, 23/7(2015-07-01), 1993-1998
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605457387 | ||
| 003 | CHVBK | ||
| 005 | 20210128100223.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20150701xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s00167-014-2839-2 |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s00167-014-2839-2 | ||
| 245 | 0 | 0 | |a Improved positioning of the tibial component in unicompartmental knee arthroplasty with patient-specific cutting blocks |h [Elektronische Daten] |c [M. Dao Trong, C. Diezi, G. Goerres, N. Helmy] |
| 520 | 3 | |a Purpose: Unicompartmental knee arthroplasty (UKA) has recently regained popularity for the treatment of osteoarthritis of the knee. Numerous authors have cited alignment as an important prognostic factor in the survival of UKA. Limb alignment affects not only the longevity of UKA by influencing wear of polyethylene, but also affects the unreplaced contralateral compartment. Malpositioning of the components may result in unequal wear patterns, thus further leading to early failure and additionally influencing clinical outcome as well. However, there is a lack of techniques to assure a high accuracy of the implant positioning. Methods: In this study, we investigated tibia component alignment of 28 medial UKAs implanted with patient-specific cutting blocks. Three patients were excluded due to bad imaging. Measurements of tibial component alignment from postoperatively computed tomography (CT) scans were compared to respective CT-based preoperative plannings to assess the accuracy of implant positioning. Results: Our results show excellent high accuracy of tibial implant position in tibial varus/valgus (Δ 0.3°±1.7°), posterior slope (Δ 1.1°±2.6°) and external rotation (Δ 1.5°±3.3°). Conclusion: We conclude that patient-specific cutting blocks improve the accuracy of tibia component positioning in unicompartmental knee arthroplasty. Level of evidence: Case series with no comparison group, Level IV. | |
| 540 | |a Springer-Verlag Berlin Heidelberg, 2014 | ||
| 690 | 7 | |a Unicompartmental knee arthroplasty |2 nationallicence | |
| 690 | 7 | |a Computed tomography |2 nationallicence | |
| 690 | 7 | |a Alignment |2 nationallicence | |
| 690 | 7 | |a Rotation |2 nationallicence | |
| 690 | 7 | |a Patient-specific cutting blocks |2 nationallicence | |
| 700 | 1 | |a Dao Trong |D M. |u Department of Orthopedic Surgery, Bürgerspital Solothurn, Schöngrünstrasse 42, 4500, Solothurn, Switzerland |4 aut | |
| 700 | 1 | |a Diezi |D C. |u Department of Orthopedic Surgery, Bürgerspital Solothurn, Schöngrünstrasse 42, 4500, Solothurn, Switzerland |4 aut | |
| 700 | 1 | |a Goerres |D G. |u Department of Radiology, Bürgerspital Solothurn, Schöngrünstrasse 42, 4500, Solothurn, Switzerland |4 aut | |
| 700 | 1 | |a Helmy |D N. |u Department of Orthopedic Surgery, Bürgerspital Solothurn, Schöngrünstrasse 42, 4500, Solothurn, Switzerland |4 aut | |
| 773 | 0 | |t Knee Surgery, Sports Traumatology, Arthroscopy |d Springer Berlin Heidelberg |g 23/7(2015-07-01), 1993-1998 |x 0942-2056 |q 23:7<1993 |1 2015 |2 23 |o 167 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00167-014-2839-2 |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a research-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s00167-014-2839-2 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Dao Trong |D M. |u Department of Orthopedic Surgery, Bürgerspital Solothurn, Schöngrünstrasse 42, 4500, Solothurn, Switzerland |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Diezi |D C. |u Department of Orthopedic Surgery, Bürgerspital Solothurn, Schöngrünstrasse 42, 4500, Solothurn, Switzerland |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Goerres |D G. |u Department of Radiology, Bürgerspital Solothurn, Schöngrünstrasse 42, 4500, Solothurn, Switzerland |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Helmy |D N. |u Department of Orthopedic Surgery, Bürgerspital Solothurn, Schöngrünstrasse 42, 4500, Solothurn, Switzerland |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Knee Surgery, Sports Traumatology, Arthroscopy |d Springer Berlin Heidelberg |g 23/7(2015-07-01), 1993-1998 |x 0942-2056 |q 23:7<1993 |1 2015 |2 23 |o 167 | ||