<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605457514</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100223.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20151201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00167-014-3287-8</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00167-014-3287-8</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Prospective evaluation of a new plate fixator for valgus-producing medial open-wedge high tibial osteotomy</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Matthias Cotic, Stephan Vogt, Matthias Feucht, Tim Saier, Philipp Minzlaff, Stefan Hinterwimmer, Andreas Imhoff]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Purpose: The purpose of this study was to prospectively evaluate the clinical, radiographic, and sports-related outcome at 24months after valgus-producing medial open-wedge high tibial osteotomy (owHTO) using a 2nd generation peek-carbon composite plate. Methods: Between 2010 and 2011, the 2nd generation PEEKPower HTO-Plate® was used for medial owHTO in 28 consecutive patients (19 men, 9 women; mean age±SD: 45±11years; mean varus deviation±SD: 4°±2°). All of the patients had an osteotomy gap height of ≤12mm without bone grafting. Visual analog scale (VAS) for pain, WOMAC score, and Lysholm score were evaluated preoperatively and at 12 and 24months postoperatively. Sports-related outcomes included the Tegner scale, and a self-designed questionnaire preoperatively and 24months postoperatively. Fixation stability of the implant was evaluated radiographically in two planes by comparing the medial proximal tibial angle (MPTA) and tibial slope 2days after medial owHTO (baseline measurements) and after implant removal (follow-up measurements). Complications were recorded during the whole study period. Results: Compared to preoperative conditions, VAS, WOMAC, and Lysholm scores improved significantly (p&lt;0.05) at the 12- and 24-month follow-up. No significant differences were found between the 12- and 24-month follow-up. After 24months, the sports frequency increased significantly (p&lt;0.05). No significant differences between baseline and follow-up measurements for the MPTA and tibial slope were observed. Total complication rate was 4%, with one patient developing non-union. Conclusion: In the clinical practice, the 2nd generation PEEKPower HTO-Plate® is a safe and efficient implant for medial owHTO without bone grafting in patients with an osteotomy gap of ≤12mm. Level of evidence: III.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">European Society of Sports Traumatology, Knee Surgery, Arthroscopy (ESSKA), 2014</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">High tibial osteotomy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Open wedge</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">2nd generation PEEKPower HTO-Plate</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Plate fixator</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Cotic</subfield>
   <subfield code="D">Matthias</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Vogt</subfield>
   <subfield code="D">Stephan</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Feucht</subfield>
   <subfield code="D">Matthias</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Saier</subfield>
   <subfield code="D">Tim</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Minzlaff</subfield>
   <subfield code="D">Philipp</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hinterwimmer</subfield>
   <subfield code="D">Stefan</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Imhoff</subfield>
   <subfield code="D">Andreas</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Knee Surgery, Sports Traumatology, Arthroscopy</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">23/12(2015-12-01), 3707-3716</subfield>
   <subfield code="x">0942-2056</subfield>
   <subfield code="q">23:12&lt;3707</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">23</subfield>
   <subfield code="o">167</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00167-014-3287-8</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00167-014-3287-8</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Cotic</subfield>
   <subfield code="D">Matthias</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Vogt</subfield>
   <subfield code="D">Stephan</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Feucht</subfield>
   <subfield code="D">Matthias</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Saier</subfield>
   <subfield code="D">Tim</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Minzlaff</subfield>
   <subfield code="D">Philipp</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hinterwimmer</subfield>
   <subfield code="D">Stefan</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Imhoff</subfield>
   <subfield code="D">Andreas</subfield>
   <subfield code="u">Department of Orthopaedic Sports Medicine, Technical University of Munich, Ismaningerstr. 22, 81675, Munich, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Knee Surgery, Sports Traumatology, Arthroscopy</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">23/12(2015-12-01), 3707-3716</subfield>
   <subfield code="x">0942-2056</subfield>
   <subfield code="q">23:12&lt;3707</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">23</subfield>
   <subfield code="o">167</subfield>
  </datafield>
 </record>
</collection>
