Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy

Verfasser / Beitragende:
[Yong Lee, Min Kim, Hae Byun, Sang Kim, Jin Kim]
Ort, Verlag, Jahr:
2015
Enthalten in:
Knee Surgery, Sports Traumatology, Arthroscopy, 23/3(2015-03-01), 846-851
Format:
Artikel (online)
ID: 605457921
LEADER caa a22 4500
001 605457921
003 CHVBK
005 20210128100226.0
007 cr unu---uuuuu
008 210128e20150301xx s 000 0 eng
024 7 0 |a 10.1007/s00167-013-2700-z  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s00167-013-2700-z 
245 0 0 |a Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy  |h [Elektronische Daten]  |c [Yong Lee, Min Kim, Hae Byun, Sang Kim, Jin Kim] 
520 3 |a Purpose: The purpose of this study was to verify a recently developed picture-archiving and communications system-photoshop method by comparing reliabilities between real-size paper template and the PACS-photoshop methods in preoperative planning of open-wedge high tibial osteotomy. Methods: A prospective case series was conducted, including patients with medial osteoarthritis undergoing open-wedge high tibial osteotomy. In the preoperative planning, the picture-archiving and communications system-photoshop method and real-size paper template method were used simultaneously in all patients. Preoperative hip-knee-ankle angle, height, and angle of the osteotomy were evaluated. The reliability of this newly devised method was evaluated, and the consistency between the two methods was also evaluated using intra-class correlation coefficient. Results: Using the picture-archiving and communications system-photoshop method, the mean correction angle and height of osteotomy gap of rater-1 were 11.7°±3.6° and 10.7±3.6mm, respectively. The mean correction angle and height of osteotomy gap of rater-2 were 12.0±2.6 and 10.8±3.6, respectively. The inter- and intra-rater reliabilities of the correction angle were 0.956~0.979 and 0.980~0.992, respectively. The inter- and intra-rater reliabilities of the height of the osteotomy gap were 0.968~0.985 and 0.971~0.994, respectively (p<0.001). Using the real-size paper template method, the correction angle and height of the osteotomy gap were 11.5°±3.4° and 10.9±3.8mm, respectively. Using the picture-archiving and communications system-photoshop method, mean values of the correction angle and height of the osteotomy gap were 11.9°±3.6° and 10.8±3.6mm, respectively. Consistency between the two methods by comparing the means of the correction angle and the height of the osteotomy gap were 0.985 and 0.985, respectively (p<0.001). Conclusions: Use of the picture-archiving and communications system-photoshop method enables direct measurement of the height of the osteotomy gap with high reliability. Level of evidence: III. 
540 |a Springer-Verlag Berlin Heidelberg, 2013 
690 7 |a High tibial osteotomy  |2 nationallicence 
690 7 |a Preoperative planning  |2 nationallicence 
690 7 |a Real-size paper template  |2 nationallicence 
690 7 |a Imaging software  |2 nationallicence 
690 7 |a Agreement  |2 nationallicence 
700 1 |a Lee  |D Yong  |u Department of Orthopedic Surgery, Gachon University Gil Hospital, Inchon, Korea  |4 aut 
700 1 |a Kim  |D Min  |u Department of Orthopedic Surgery, Seoul Paik Hospital, Inje University, Jeo Dong 2Ga, Gung Gu, Seoul, Korea  |4 aut 
700 1 |a Byun  |D Hae  |u School of Information Technology, Sungshin Women's University, Seoul, Korea  |4 aut 
700 1 |a Kim  |D Sang  |u Department of Orthopedic Surgery, Seoul Paik Hospital, Inje University, Jeo Dong 2Ga, Gung Gu, Seoul, Korea  |4 aut 
700 1 |a Kim  |D Jin  |u Department of Orthopedic Surgery, Seoul Paik Hospital, Inje University, Jeo Dong 2Ga, Gung Gu, Seoul, Korea  |4 aut 
773 0 |t Knee Surgery, Sports Traumatology, Arthroscopy  |d Springer Berlin Heidelberg  |g 23/3(2015-03-01), 846-851  |x 0942-2056  |q 23:3<846  |1 2015  |2 23  |o 167 
856 4 0 |u https://doi.org/10.1007/s00167-013-2700-z  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s00167-013-2700-z  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Lee  |D Yong  |u Department of Orthopedic Surgery, Gachon University Gil Hospital, Inchon, Korea  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kim  |D Min  |u Department of Orthopedic Surgery, Seoul Paik Hospital, Inje University, Jeo Dong 2Ga, Gung Gu, Seoul, Korea  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Byun  |D Hae  |u School of Information Technology, Sungshin Women's University, Seoul, Korea  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kim  |D Sang  |u Department of Orthopedic Surgery, Seoul Paik Hospital, Inje University, Jeo Dong 2Ga, Gung Gu, Seoul, Korea  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Kim  |D Jin  |u Department of Orthopedic Surgery, Seoul Paik Hospital, Inje University, Jeo Dong 2Ga, Gung Gu, Seoul, Korea  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Knee Surgery, Sports Traumatology, Arthroscopy  |d Springer Berlin Heidelberg  |g 23/3(2015-03-01), 846-851  |x 0942-2056  |q 23:3<846  |1 2015  |2 23  |o 167