<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605458499</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100229.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20151001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00167-015-3768-4</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00167-015-3768-4</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Robotic axial lower leg testing: repeatability and reproducibility</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Thomas Branch, Shaun Stinton, Maya Sternberg, William Hutton, Frédéric Lavoie, Christian Guier, Philippe Neyret]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Purpose: The purpose of this study was to determine the test-retest reliability and the repeatability over multiple days of a robotic testing device when used to measure laxity of the lower leg during a simulated dial test. Methods: Ten healthy subjects were evaluated using an instrumented robotic lower leg testing system over 4days. Three testing cycles were performed each day. Each leg was rotated into external and then internal rotation by servomotors until a torque threshold of 5.65N m was reached. Load-deformation curves were generated from torque and rotation data. Both average-measure and single-measure intraclass correlation coefficients (ICC) were compared across the curves. ICC scores were also compared for features of the curves including: maximum external rotation at −5.65N m of torque, maximum internal rotation at 5.65N m of torque, rotation at torque 0, compliance (slope of load-deformation curve) at torque 0, endpoint compliance in external rotation, endpoint compliance in internal rotation, and play at torque 0. Play at torque 0 was defined as the width of the hysteresis curve at torque 0. Results: Average-measure ICC scores and test-retest scores were &gt;0.95 along the entire load-deformation curve except around zero torque. ICC scores at maximum internal and external rotation ranged from 0.87 to 0.99 across the left and right knees. ICC scores for the other features of the curves ranged from 0.61 to 0.98. The standard error of the mean ranged from 0.0497 to 1.1712. Conclusions: The robotic testing device in this study proved to be reliable for testing a subject multiple times both within the same day and over multiple days. These findings suggest that the device can provide a level of reliability in rotational testing that allows for clinical use of test results. Objective laxity data can improve consistency and accuracy in diagnosing knee injuries and may enable more effective treatment.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">The Author(s), 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Knee laxity</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Manual examination</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Robotic testing</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Reliability</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Rotational laxity</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Branch</subfield>
   <subfield code="D">Thomas</subfield>
   <subfield code="u">University Orthopedics, Decatur, GA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Stinton</subfield>
   <subfield code="D">Shaun</subfield>
   <subfield code="u">ArthroMetrix, LLC, 441 Armour Place NE, 30324, Atlanta, GA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Sternberg</subfield>
   <subfield code="D">Maya</subfield>
   <subfield code="u">Quartiles Consulting, Atlanta, GA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Hutton</subfield>
   <subfield code="D">William</subfield>
   <subfield code="u">Department of Orthopaedics, Emory University School of Medicine, Atlanta, GA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Lavoie</subfield>
   <subfield code="D">Frédéric</subfield>
   <subfield code="u">Hôpital Notre-Dame du CHUM, Montréal, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Guier</subfield>
   <subfield code="D">Christian</subfield>
   <subfield code="u">San Francisco Sports Medicine and Orthopaedic Surgery, San Francisco, CA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Neyret</subfield>
   <subfield code="D">Philippe</subfield>
   <subfield code="u">Department of Orthopaedic Surgery, Centre Albert Trillat, Hôpital de la Croix-Rousse, Lyon, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Knee Surgery, Sports Traumatology, Arthroscopy</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">23/10(2015-10-01), 2892-2899</subfield>
   <subfield code="x">0942-2056</subfield>
   <subfield code="q">23:10&lt;2892</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">23</subfield>
   <subfield code="o">167</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00167-015-3768-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00167-015-3768-4</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Branch</subfield>
   <subfield code="D">Thomas</subfield>
   <subfield code="u">University Orthopedics, Decatur, GA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Stinton</subfield>
   <subfield code="D">Shaun</subfield>
   <subfield code="u">ArthroMetrix, LLC, 441 Armour Place NE, 30324, Atlanta, GA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Sternberg</subfield>
   <subfield code="D">Maya</subfield>
   <subfield code="u">Quartiles Consulting, Atlanta, GA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Hutton</subfield>
   <subfield code="D">William</subfield>
   <subfield code="u">Department of Orthopaedics, Emory University School of Medicine, Atlanta, GA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Lavoie</subfield>
   <subfield code="D">Frédéric</subfield>
   <subfield code="u">Hôpital Notre-Dame du CHUM, Montréal, Canada</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Guier</subfield>
   <subfield code="D">Christian</subfield>
   <subfield code="u">San Francisco Sports Medicine and Orthopaedic Surgery, San Francisco, CA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Neyret</subfield>
   <subfield code="D">Philippe</subfield>
   <subfield code="u">Department of Orthopaedic Surgery, Centre Albert Trillat, Hôpital de la Croix-Rousse, Lyon, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Knee Surgery, Sports Traumatology, Arthroscopy</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">23/10(2015-10-01), 2892-2899</subfield>
   <subfield code="x">0942-2056</subfield>
   <subfield code="q">23:10&lt;2892</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">23</subfield>
   <subfield code="o">167</subfield>
  </datafield>
 </record>
</collection>
