<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">60545972X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100235.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20150501xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00167-014-2849-0</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00167-014-2849-0</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">No radiographic difference between patient-specific guiding and conventional Oxford UKA surgery</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Bart Kerens, Martijn Schotanus, Bert Boonen, Nanne Kort]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Purpose: Implant position is an important factor in unicompartmental knee arthroplasty (UKA) surgery. Results on conventional UKA alignment are commonly described in literature. Patient-specific guiding (PSG) is a new technique for positioning the Oxford UKA. Our hypothesis is that PSG improves component position without affecting the HKA angle. Methods: This prospective study compares the results of our first thirty cases of cementless Oxford UKA using PSG with thirty cases using conventional outlining. Baseline characteristics for both groups were identical. Details on handling of the guide, estimated blood loss and operation time were recorded. Postoperative screened radiographs and standing long-leg radiographs of both groups were compared. Results: Median AP position of the femoral component was 3 degrees varus (−5 to 9) using PSG versus 2 degrees varus (−10 to 8) for the conventional group. For the femoral flexion, this was 9 degrees flexion (0-16) using PSG versus 12 degrees flexion (0-20). The tibial median AP position was 1 degree varus (−3 to 7) using PSG versus 2 degrees varus (−5 to 10). The median tibial posterior slope was 5 degrees (1-10) using PSG versus 5 degrees (0-12). All guides aligned well. No conversion to conventional outlining was performed, and no significant changes had to be made to the original approved plan. Operation time, estimated blood loss and postoperative haemoglobin drop were not significantly different between both groups. Discussion: Implant position was not different between both groups, even in the early phase of the learning curve. Perioperative results were not different between both groups. Level of evidence: III.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Berlin Heidelberg, 2014</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Unicompartmental knee arthroplasty</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Patient specific</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Oxford</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Guiding</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kerens</subfield>
   <subfield code="D">Bart</subfield>
   <subfield code="u">Department of Orthopedic Surgery, AZ Monica, Deurne, Belgium</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Schotanus</subfield>
   <subfield code="D">Martijn</subfield>
   <subfield code="u">Department of Orthopedic Surgery, Orbis Medisch Centrum, Sittard, The Netherlands</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Boonen</subfield>
   <subfield code="D">Bert</subfield>
   <subfield code="u">Department of Surgery, VieCuri Medical Centre, Venlo, The Netherlands</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kort</subfield>
   <subfield code="D">Nanne</subfield>
   <subfield code="u">Department of Orthopedic Surgery, Orbis Medisch Centrum, Sittard, The Netherlands</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Knee Surgery, Sports Traumatology, Arthroscopy</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">23/5(2015-05-01), 1324-1329</subfield>
   <subfield code="x">0942-2056</subfield>
   <subfield code="q">23:5&lt;1324</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">23</subfield>
   <subfield code="o">167</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00167-014-2849-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00167-014-2849-0</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kerens</subfield>
   <subfield code="D">Bart</subfield>
   <subfield code="u">Department of Orthopedic Surgery, AZ Monica, Deurne, Belgium</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Schotanus</subfield>
   <subfield code="D">Martijn</subfield>
   <subfield code="u">Department of Orthopedic Surgery, Orbis Medisch Centrum, Sittard, The Netherlands</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Boonen</subfield>
   <subfield code="D">Bert</subfield>
   <subfield code="u">Department of Surgery, VieCuri Medical Centre, Venlo, The Netherlands</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kort</subfield>
   <subfield code="D">Nanne</subfield>
   <subfield code="u">Department of Orthopedic Surgery, Orbis Medisch Centrum, Sittard, The Netherlands</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Knee Surgery, Sports Traumatology, Arthroscopy</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">23/5(2015-05-01), 1324-1329</subfield>
   <subfield code="x">0942-2056</subfield>
   <subfield code="q">23:5&lt;1324</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">23</subfield>
   <subfield code="o">167</subfield>
  </datafield>
 </record>
</collection>
