Evaluation of a toric intraocular lens with open-C-loop haptic

Verfasser / Beitragende:
[Renate Rubey, Kata Mihaltz, Andreas Scholler, Sibylla Richter-Mueksch, Saskia Maca, Georg Heinze, Birgit Weingessel, Pia-Veronika Vécsei-Marlovits]
Ort, Verlag, Jahr:
2015
Enthalten in:
Spektrum der Augenheilkunde, 29/3(2015-06-01), 86-91
Format:
Artikel (online)
ID: 605465177
LEADER caa a22 4500
001 605465177
003 CHVBK
005 20210128100301.0
007 cr unu---uuuuu
008 210128e20150601xx s 000 0 eng
024 7 0 |a 10.1007/s00717-014-0248-z  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s00717-014-0248-z 
245 0 0 |a Evaluation of a toric intraocular lens with open-C-loop haptic  |h [Elektronische Daten]  |c [Renate Rubey, Kata Mihaltz, Andreas Scholler, Sibylla Richter-Mueksch, Saskia Maca, Georg Heinze, Birgit Weingessel, Pia-Veronika Vécsei-Marlovits] 
246 1 |a Vergleichende Analyse des refraktiven und aberrometrischen Outcome nach Implantation von 2 verschiedenen torischen Intraokularlinen 
520 3 |a Purpose: To assess the rotational stability of a single-piece intraocular lens (IOL) with C-loop haptic during the first six postoperative months. Setting: Department of Ophthalmology, Hietzing Hospital, Vienna, Austria. Design: Prospective clinical trial. Methods: This study enrolled consecutive patients with 1.5 diopters (D) or more of preexisting corneal astigmatism having cataract surgery. Patients had phacoemulsification with implantation of the open-C-loop toric IOL Lentis Unico LU-312T through a 2.5mm astigmatically neutral incision. Uncorrected distance visual acuity (UDVA) and best corrected visual acuity (BCVA), refraction, keratometry, and the cylinder axis of the toric IOL were measured. Postoperative examinations were scheduled at week 1, month 1, month 3, and month 6. Results: A total of 60 eyes of 39 patients were evaluated. The mean preoperative refractive astigmatism was 2.82±1.34D (SD) and the mean keratometric astigmatism 2.33±1.10D, respectively. Six months postoperatively the refractive cylinder decreased significantly to 1.12±0.63D. The mean postoperative UDVA was 79.05±7.48 letters, improving to 83.78±5.60 letters BCVA. The mean IOL rotation was 5.22±5.82° (range: 0.0-32) at month 6 with less than 10° in 88.3% of eyes. Five eyes needed reoperation due to IOL misalignment. Conclusions: The Lentis LU-312T showed some tendency to rotate for up to 6 months. The C-loop design seems to be less suitable for toric IOLs. 
540 |a Springer-Verlag Wien, 2014 
690 7 |a Toric IOL  |2 nationallicence 
690 7 |a Rotational stability  |2 nationallicence 
690 7 |a Astigmatism  |2 nationallicence 
690 7 |a torische HKL  |2 nationallicence 
690 7 |a Rotationsstabilität  |2 nationallicence 
690 7 |a Astigmatismus  |2 nationallicence 
700 1 |a Rubey  |D Renate  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
700 1 |a Mihaltz  |D Kata  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
700 1 |a Scholler  |D Andreas  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
700 1 |a Richter-Mueksch  |D Sibylla  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
700 1 |a Maca  |D Saskia  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
700 1 |a Heinze  |D Georg  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
700 1 |a Weingessel  |D Birgit  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
700 1 |a Vécsei-Marlovits  |D Pia-Veronika  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
773 0 |t Spektrum der Augenheilkunde  |d Springer Vienna  |g 29/3(2015-06-01), 86-91  |x 0930-4282  |q 29:3<86  |1 2015  |2 29  |o 717 
856 4 0 |u https://doi.org/10.1007/s00717-014-0248-z  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s00717-014-0248-z  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Rubey  |D Renate  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Mihaltz  |D Kata  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Scholler  |D Andreas  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Richter-Mueksch  |D Sibylla  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Maca  |D Saskia  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Heinze  |D Georg  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Weingessel  |D Birgit  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Vécsei-Marlovits  |D Pia-Veronika  |u Department of Ophthalmology, Hietzing Hospital, Wolkersbergenstraße 1, 1130, Vienna, Austria  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Spektrum der Augenheilkunde  |d Springer Vienna  |g 29/3(2015-06-01), 86-91  |x 0930-4282  |q 29:3<86  |1 2015  |2 29  |o 717