<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605465304</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100302.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20151201xx      s     000 0 ger  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00717-015-0272-7</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00717-015-0272-7</subfield>
  </datafield>
  <datafield tag="100" ind1="1" ind2=" ">
   <subfield code="a">Emesz</subfield>
   <subfield code="D">Martin</subfield>
   <subfield code="u">Universitätsklinik für Augenheilkunde und Optometrie, Paracelsus Medizinische Privatuniversität Salzburg, Müllner Hauptstraße 48, 5020, Salzburg, Österreich</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="245" ind1="1" ind2="0">
   <subfield code="a">Bindehaut-, Lid- und Orbitarekonstruktion</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Martin Emesz]</subfield>
  </datafield>
  <datafield tag="246" ind1="0" ind2=" ">
   <subfield code="a">Methods of reconstructing the conjunctiva, the eyelid and the orbit</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">Zusammenfassung: Es werden Methoden zur Rekonstruktion von Defekten der Lid- und Bulbusbindehaut nach Tumorchirurgie und in der Rehabilitation von vernarbenden Schleimhauterkrankungen dargestellt. Bei der Wiederherstellung des vorderen und hinteren Lidblattes zur Therapie von durchgreifenden Ober- und Unterliddefekten wird die Verwendung von lokalen Verschiebelappen kombiniert mit freien Gewebetransplantaten beschrieben. Größere Defekte des Weichteilgewebes der Orbita und knöcherne Orbitawanddefekte können durch alloplastisches Material und autologe Transplantate ersetzt werden. Unterschiedliche rekonstruktive Methoden werden präsentiert, verglichen und neuen konservativen Vorgangsweisen gegenübergestellt.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Wien, 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Bindehaut</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Symblepharon</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Exenteration</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Enukleation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Eviszeration</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Lidrekonstruktion</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Titan Mesh</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Osteomyokutanes Transplantat</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Conjunctiva</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Enuclation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Evisceration</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Eyelid reconstruction</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Titan mesh</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Osteomyocutanous flap</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Spektrum der Augenheilkunde</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">29/5-6(2015-12-01), 174-178</subfield>
   <subfield code="x">0930-4282</subfield>
   <subfield code="q">29:5-6&lt;174</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">29</subfield>
   <subfield code="o">717</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00717-015-0272-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00717-015-0272-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">100</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Emesz</subfield>
   <subfield code="D">Martin</subfield>
   <subfield code="u">Universitätsklinik für Augenheilkunde und Optometrie, Paracelsus Medizinische Privatuniversität Salzburg, Müllner Hauptstraße 48, 5020, Salzburg, Österreich</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Spektrum der Augenheilkunde</subfield>
   <subfield code="d">Springer Vienna</subfield>
   <subfield code="g">29/5-6(2015-12-01), 174-178</subfield>
   <subfield code="x">0930-4282</subfield>
   <subfield code="q">29:5-6&lt;174</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">29</subfield>
   <subfield code="o">717</subfield>
  </datafield>
 </record>
</collection>
