Interaction of 15 priority substances for water monitoring at ngL−1 levels with glass, aluminium and fluorinated polyethylene bottles for the containment of water reference materials

Verfasser / Beitragende:
[Saioa Elordui-Zapatarietxe, Ina Fettig, Janine Richter, Rosemarie Philipp, Fanny Gantois, Béatrice Lalère, Claudia Swart, Håkan Emteborg]
Ort, Verlag, Jahr:
2015
Enthalten in:
Accreditation and Quality Assurance, 20/6(2015-12-01), 447-455
Format:
Artikel (online)
ID: 605465614
LEADER caa a22 4500
001 605465614
003 CHVBK
005 20210128100303.0
007 cr unu---uuuuu
008 210128e20151201xx s 000 0 eng
024 7 0 |a 10.1007/s00769-015-1150-3  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s00769-015-1150-3 
245 0 0 |a Interaction of 15 priority substances for water monitoring at ngL−1 levels with glass, aluminium and fluorinated polyethylene bottles for the containment of water reference materials  |h [Elektronische Daten]  |c [Saioa Elordui-Zapatarietxe, Ina Fettig, Janine Richter, Rosemarie Philipp, Fanny Gantois, Béatrice Lalère, Claudia Swart, Håkan Emteborg] 
520 3 |a Certified water reference materials are currently not available for most of the hydrophobic organic pollutants listed in the EU Water Framework Directive. To find the most suitable container type for subsequent reference material productions, feasibility studies for the preparation of waters with polycyclic aromatic hydrocarbons (PAHs), polybrominated diphenyl ethers (PBDEs) and tributyltin (TBT) close to environmental quality standards in water have been performed. Due to the hydrophobic nature of these compounds and their tendency to adsorb onto container walls, an adequate selection of the most appropriate material for containment, storage and transport of water reference materials is crucial. Three different materials (aluminium, amber glass and fluorinated polyethylene, FPE) and three volumes (500/600 mL, 1000/1200 mL and 2000/3000mL, depending on commercial availability) were tested at ngL−1 level of the target compounds. FPE shows by far the highest loss of analytes due to adsorption onto the container walls for all compounds studied. Aluminium and glass are equally suited for PAHs and PBDEs, but aluminium is unsuitable as container material for TBT due to acid cleaning requirements. The volume of the containers had no dramatic effect on the adsorption behaviour of target compounds for the different volumes tested. 
540 |a The Author(s), 2015 
690 7 |a Water Framework Directive  |2 nationallicence 
690 7 |a Reference materials  |2 nationallicence 
690 7 |a Hydrophobic organic pollutants  |2 nationallicence 
690 7 |a Bottles  |2 nationallicence 
690 7 |a Adsorption  |2 nationallicence 
690 7 |a Glass  |2 nationallicence 
690 7 |a Aluminium  |2 nationallicence 
690 7 |a Fluorinated polyethylene  |2 nationallicence 
700 1 |a Elordui-Zapatarietxe  |D Saioa  |u European Commission, Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, 2440, Geel, Belgium  |4 aut 
700 1 |a Fettig  |D Ina  |u Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany  |4 aut 
700 1 |a Richter  |D Janine  |u Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany  |4 aut 
700 1 |a Philipp  |D Rosemarie  |u Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany  |4 aut 
700 1 |a Gantois  |D Fanny  |u Laboratoire National de Métrologie et d'Essais (LNE), 5, Avenue Albert Bartholomé, 75015, Paris, France  |4 aut 
700 1 |a Lalère  |D Béatrice  |u Laboratoire National de Métrologie et d'Essais (LNE), 5, Avenue Albert Bartholomé, 75015, Paris, France  |4 aut 
700 1 |a Swart  |D Claudia  |u Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116, Braunschweig, Germany  |4 aut 
700 1 |a Emteborg  |D Håkan  |u European Commission, Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, 2440, Geel, Belgium  |4 aut 
773 0 |t Accreditation and Quality Assurance  |d Springer Berlin Heidelberg  |g 20/6(2015-12-01), 447-455  |x 0949-1775  |q 20:6<447  |1 2015  |2 20  |o 769 
856 4 0 |u https://doi.org/10.1007/s00769-015-1150-3  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s00769-015-1150-3  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Elordui-Zapatarietxe  |D Saioa  |u European Commission, Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, 2440, Geel, Belgium  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Fettig  |D Ina  |u Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Richter  |D Janine  |u Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Philipp  |D Rosemarie  |u Bundesanstalt für Materialforschung und -prüfung (BAM), Richard-Willstätter-Str. 11, 12489, Berlin, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Gantois  |D Fanny  |u Laboratoire National de Métrologie et d'Essais (LNE), 5, Avenue Albert Bartholomé, 75015, Paris, France  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Lalère  |D Béatrice  |u Laboratoire National de Métrologie et d'Essais (LNE), 5, Avenue Albert Bartholomé, 75015, Paris, France  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Swart  |D Claudia  |u Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116, Braunschweig, Germany  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Emteborg  |D Håkan  |u European Commission, Joint Research Centre, Institute for Reference Materials and Measurements (IRMM), Retieseweg 111, 2440, Geel, Belgium  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Accreditation and Quality Assurance  |d Springer Berlin Heidelberg  |g 20/6(2015-12-01), 447-455  |x 0949-1775  |q 20:6<447  |1 2015  |2 20  |o 769