Revision of ISO Guide 33: good practice in using reference materials
Gespeichert in:
Verfasser / Beitragende:
[Adriaan van der Veen]
Ort, Verlag, Jahr:
2015
Enthalten in:
Accreditation and Quality Assurance, 20/6(2015-12-01), 529-532
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605465622 | ||
| 003 | CHVBK | ||
| 005 | 20210128100303.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20151201xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s00769-015-1167-7 |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s00769-015-1167-7 | ||
| 100 | 1 | |a van der Veen |D Adriaan |u Chemistry Group, Van Swinden Laboratorium, Delft, The Netherlands |4 aut | |
| 245 | 1 | 0 | |a Revision of ISO Guide 33: good practice in using reference materials |h [Elektronische Daten] |c [Adriaan van der Veen] |
| 520 | 3 | |a ISO/REMCO, the Committee on Reference Materials of the International Organisation for Standardisation, has revised ISO Guide 33. In doing so, the document now provides a more comprehensive coverage of the mainstream applications of reference materials (RMs) and certified reference materials (CRMs). Unlike its predecessor, the new ISO Guide 33 now also covers calibration as one of the uses and aspects of preparing calibration RMs from pure materials, as done in many testing laboratories. These aspects were felt to be missing in guidance to laboratories. The Guide is now well aligned with the Guide to the Expression of Uncertainty in Measurement and its supplements. Many applications of RMs and CRMs in particular require the evaluation of measurement uncertainty or have an impact on it. Last but not least, the Guide also contains a specific clause dealing with the various aspects of selecting an RM for a particular purpose. | |
| 540 | |a Springer-Verlag Berlin Heidelberg, 2015 | ||
| 690 | 7 | |a CRM |2 nationallicence | |
| 690 | 7 | |a RM |2 nationallicence | |
| 690 | 7 | |a ISO Guide 33 |2 nationallicence | |
| 690 | 7 | |a Accreditation |2 nationallicence | |
| 690 | 7 | |a Quality control |2 nationallicence | |
| 690 | 7 | |a Calibration |2 nationallicence | |
| 690 | 7 | |a Method validation |2 nationallicence | |
| 773 | 0 | |t Accreditation and Quality Assurance |d Springer Berlin Heidelberg |g 20/6(2015-12-01), 529-532 |x 0949-1775 |q 20:6<529 |1 2015 |2 20 |o 769 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s00769-015-1167-7 |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a research-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s00769-015-1167-7 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 100 |E 1- |a van der Veen |D Adriaan |u Chemistry Group, Van Swinden Laboratorium, Delft, The Netherlands |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Accreditation and Quality Assurance |d Springer Berlin Heidelberg |g 20/6(2015-12-01), 529-532 |x 0949-1775 |q 20:6<529 |1 2015 |2 20 |o 769 | ||