Comparison of exact matching and calibration curve quantification methods for glucose in human serum GC-IDMS analysis and their application for the development of certified reference materials

Verfasser / Beitragende:
[Juliana Barrabin, Bruno Garrido, Gabriella Machado, Wagner Wollinger, Rodrigo Freitas, Ana Feliciano, Marcia de la Cruz]
Ort, Verlag, Jahr:
2015
Enthalten in:
Accreditation and Quality Assurance, 20/6(2015-12-01), 483-493
Format:
Artikel (online)
ID: 605465649
LEADER caa a22 4500
001 605465649
003 CHVBK
005 20210128100303.0
007 cr unu---uuuuu
008 210128e20151201xx s 000 0 eng
024 7 0 |a 10.1007/s00769-015-1168-6  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s00769-015-1168-6 
245 0 0 |a Comparison of exact matching and calibration curve quantification methods for glucose in human serum GC-IDMS analysis and their application for the development of certified reference materials  |h [Elektronische Daten]  |c [Juliana Barrabin, Bruno Garrido, Gabriella Machado, Wagner Wollinger, Rodrigo Freitas, Ana Feliciano, Marcia de la Cruz] 
520 3 |a The establishment of a precise and accurate method for the determination of the analyte is the first step in the development of certified reference materials (CRMs), which play a key role in metrological traceability. To assist the production of a glucose CRM in human serum for clinical chemistry routine tests, we developed a gas chromatography-isotope dilution mass spectrometry method using trimethylsilylation and performed two calibration techniques: exact matching approach and calibration curve. Performance of the method and calibration techniques were evaluated for their suitability for the characterization of a CRM candidate carrying out studies to assign the property value and to assure homogeneity as well as short- and long-term stability. Both calibration approaches were equivalent in terms of accuracy and precision and presented bias lower than 1.0% with relative standard deviations lower than 3.0%. Relative measurement uncertainties obtained with the exact matching approach calibration method were between 1.0 % and 2.5% and were lower than the ones obtained with calibration curve method. This finding justifies the use of the time-consuming exact matching method for the assignment of the property value, while the calibration curve procedure suits the other certification studies. 
540 |a Springer-Verlag Berlin Heidelberg, 2015 
690 7 |a Exact matching approach  |2 nationallicence 
690 7 |a Uncertainty of measurement  |2 nationallicence 
690 7 |a GC-IDMS  |2 nationallicence 
690 7 |a Glucose analysis  |2 nationallicence 
690 7 |a Certified reference material  |2 nationallicence 
700 1 |a Barrabin  |D Juliana  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
700 1 |a Garrido  |D Bruno  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
700 1 |a Machado  |D Gabriella  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
700 1 |a Wollinger  |D Wagner  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
700 1 |a Freitas  |D Rodrigo  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
700 1 |a Feliciano  |D Ana  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
700 1 |a de la Cruz  |D Marcia  |u Institute of Chemistry, Federal University of Rio de Janeiro - UFRJ, 21941-909, Rio de Janeiro, RJ, Brazil  |4 aut 
773 0 |t Accreditation and Quality Assurance  |d Springer Berlin Heidelberg  |g 20/6(2015-12-01), 483-493  |x 0949-1775  |q 20:6<483  |1 2015  |2 20  |o 769 
856 4 0 |u https://doi.org/10.1007/s00769-015-1168-6  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s00769-015-1168-6  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Barrabin  |D Juliana  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Garrido  |D Bruno  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Machado  |D Gabriella  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Wollinger  |D Wagner  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Freitas  |D Rodrigo  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Feliciano  |D Ana  |u National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a de la Cruz  |D Marcia  |u Institute of Chemistry, Federal University of Rio de Janeiro - UFRJ, 21941-909, Rio de Janeiro, RJ, Brazil  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Accreditation and Quality Assurance  |d Springer Berlin Heidelberg  |g 20/6(2015-12-01), 483-493  |x 0949-1775  |q 20:6<483  |1 2015  |2 20  |o 769