<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605465649</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100303.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20151201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00769-015-1168-6</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00769-015-1168-6</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Comparison of exact matching and calibration curve quantification methods for glucose in human serum GC-IDMS analysis and their application for the development of certified reference materials</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Juliana Barrabin, Bruno Garrido, Gabriella Machado, Wagner Wollinger, Rodrigo Freitas, Ana Feliciano, Marcia de la Cruz]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The establishment of a precise and accurate method for the determination of the analyte is the first step in the development of certified reference materials (CRMs), which play a key role in metrological traceability. To assist the production of a glucose CRM in human serum for clinical chemistry routine tests, we developed a gas chromatography-isotope dilution mass spectrometry method using trimethylsilylation and performed two calibration techniques: exact matching approach and calibration curve. Performance of the method and calibration techniques were evaluated for their suitability for the characterization of a CRM candidate carrying out studies to assign the property value and to assure homogeneity as well as short- and long-term stability. Both calibration approaches were equivalent in terms of accuracy and precision and presented bias lower than 1.0% with relative standard deviations lower than 3.0%. Relative measurement uncertainties obtained with the exact matching approach calibration method were between 1.0 % and 2.5% and were lower than the ones obtained with calibration curve method. This finding justifies the use of the time-consuming exact matching method for the assignment of the property value, while the calibration curve procedure suits the other certification studies.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Berlin Heidelberg, 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Exact matching approach</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Uncertainty of measurement</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">GC-IDMS</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Glucose analysis</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Certified reference material</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Barrabin</subfield>
   <subfield code="D">Juliana</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Garrido</subfield>
   <subfield code="D">Bruno</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Machado</subfield>
   <subfield code="D">Gabriella</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Wollinger</subfield>
   <subfield code="D">Wagner</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Freitas</subfield>
   <subfield code="D">Rodrigo</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Feliciano</subfield>
   <subfield code="D">Ana</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">de la Cruz</subfield>
   <subfield code="D">Marcia</subfield>
   <subfield code="u">Institute of Chemistry, Federal University of Rio de Janeiro - UFRJ, 21941-909, Rio de Janeiro, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Accreditation and Quality Assurance</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">20/6(2015-12-01), 483-493</subfield>
   <subfield code="x">0949-1775</subfield>
   <subfield code="q">20:6&lt;483</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">20</subfield>
   <subfield code="o">769</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00769-015-1168-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00769-015-1168-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Barrabin</subfield>
   <subfield code="D">Juliana</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Garrido</subfield>
   <subfield code="D">Bruno</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Machado</subfield>
   <subfield code="D">Gabriella</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Wollinger</subfield>
   <subfield code="D">Wagner</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Freitas</subfield>
   <subfield code="D">Rodrigo</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Feliciano</subfield>
   <subfield code="D">Ana</subfield>
   <subfield code="u">National Institute of Metrology, Quality and Technology - Inmetro, Av Nossa Senhora das Graças, 50, 25250-020, Duque de Caxias, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">de la Cruz</subfield>
   <subfield code="D">Marcia</subfield>
   <subfield code="u">Institute of Chemistry, Federal University of Rio de Janeiro - UFRJ, 21941-909, Rio de Janeiro, RJ, Brazil</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Accreditation and Quality Assurance</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">20/6(2015-12-01), 483-493</subfield>
   <subfield code="x">0949-1775</subfield>
   <subfield code="q">20:6&lt;483</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">20</subfield>
   <subfield code="o">769</subfield>
  </datafield>
 </record>
</collection>
