Microbiology proficiency testing of Brazilian accredited laboratories

Verfasser / Beitragende:
[Priscila Yuvamoto]
Ort, Verlag, Jahr:
2015
Enthalten in:
Accreditation and Quality Assurance, 20/4(2015-08-01), 319-323
Format:
Artikel (online)
ID: 605465959
LEADER caa a22 4500
001 605465959
003 CHVBK
005 20210128100305.0
007 cr unu---uuuuu
008 210128e20150801xx s 000 0 eng
024 7 0 |a 10.1007/s00769-015-1126-3  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s00769-015-1126-3 
100 1 |a Yuvamoto  |D Priscila  |u General Coordination for Accreditation (Cgcre), National Institute of Metrology, Quality and Technology (Inmetro), Av. Nossa Senhora das Graças, 50, Xerém, 25250-020, Rio de Janeiro, RJ, Brazil  |4 aut 
245 1 0 |a Microbiology proficiency testing of Brazilian accredited laboratories  |h [Elektronische Daten]  |c [Priscila Yuvamoto] 
520 3 |a Proficiency testing (PT) schemes are an important tool to evaluate the performance of the laboratories. In microbiological testing, one of the most frequent areas for testing in Brazilian accredited laboratories, there are specific challenges related to the variability in measurement results (organisms, methods, matrices and others) all the more as critical and regulated areas are covered. The aim of this study was to obtain an overview about the PT activities within microbiology in order to learn about the local difficulties and possibilities. A questionnaire was sent to the accredited laboratories, and the answers will be used by CGCRE (Brazilian accreditation body) to establish policies, standardize the practices to the laboratories and also provide an orientation to PT providers. 
540 |a Springer-Verlag Berlin Heidelberg, 2015 
690 7 |a Laboratory accreditation  |2 nationallicence 
690 7 |a Proficiency testing  |2 nationallicence 
690 7 |a Microbiological testing  |2 nationallicence 
690 7 |a Environmental area  |2 nationallicence 
690 7 |a Foodstuff area  |2 nationallicence 
773 0 |t Accreditation and Quality Assurance  |d Springer Berlin Heidelberg  |g 20/4(2015-08-01), 319-323  |x 0949-1775  |q 20:4<319  |1 2015  |2 20  |o 769 
856 4 0 |u https://doi.org/10.1007/s00769-015-1126-3  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s00769-015-1126-3  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 100  |E 1-  |a Yuvamoto  |D Priscila  |u General Coordination for Accreditation (Cgcre), National Institute of Metrology, Quality and Technology (Inmetro), Av. Nossa Senhora das Graças, 50, Xerém, 25250-020, Rio de Janeiro, RJ, Brazil  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Accreditation and Quality Assurance  |d Springer Berlin Heidelberg  |g 20/4(2015-08-01), 319-323  |x 0949-1775  |q 20:4<319  |1 2015  |2 20  |o 769