<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605465991</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100305.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20151001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00769-015-1173-9</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00769-015-1173-9</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Comparison of different approaches used for the interpretation and presentation of PT results</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Aida Jotanovic, Semsa Suljagic]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">The laboratory for precious metals within the Institute of Metrology of Bosnia and Herzegovina acts as a state reference laboratory in the field of quality control of articles manufactured of precious metals, e.g. jewellery. It disseminates reference values through the organisation of proficiency testing (PT) schemes. Two separate PT schemes for the determination of mass fraction of gold in typical jewellery alloys were conducted in 2013 and 2014. Laboratories taking part in these PT schemes are affiliated to the National Metrology Institutes of several countries and two private goldsmith laboratories. Different approaches in the design of the PT schemes and the evaluation of the PT results were used with the purpose of exploring their features regarding the interpretation of the results. For PT.13, z-scores were used as laboratory performance indicators. The assigned value and the standard deviation for proficiency assessment were calculated from the results of the participating laboratories by applying robust statistic. z-score and z′-score were used as performance indicators for the scheme PT.14, and the assigned value of the test sample and its measurement uncertainty were determined by the PT provider. The standard deviation of the testing method of 0.5mg/g as prescribed in ISO 11426 as fit for purpose in the field of interest is used as standard deviation for proficiency assessment σ p. By comparing the z-scores and z′-scores assigned to the PT.14 results, it is evident that the measurement uncertainty of the assigned value provided by the PT provider does not affect the overall successfulness of the participants. The Q-score based on relative deviation was used as an alternative approach to identify future partners in PT schemes with the purpose of reference value assignment (Q≤0.05).</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Berlin Heidelberg, 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">PT schemes</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Assigned value</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">z -score</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">z ′-score</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Q -score</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Gold alloy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Jotanovic</subfield>
   <subfield code="D">Aida</subfield>
   <subfield code="u">Institute of Metrology of Bosnia and Herzegovina - IMBIH, Dolina 6, Sarajevo, Bosnia and Herzegovina</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Suljagic</subfield>
   <subfield code="D">Semsa</subfield>
   <subfield code="u">Institute of Metrology of Bosnia and Herzegovina - IMBIH, Dolina 6, Sarajevo, Bosnia and Herzegovina</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Accreditation and Quality Assurance</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">20/5(2015-10-01), 395-399</subfield>
   <subfield code="x">0949-1775</subfield>
   <subfield code="q">20:5&lt;395</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">20</subfield>
   <subfield code="o">769</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00769-015-1173-9</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00769-015-1173-9</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Jotanovic</subfield>
   <subfield code="D">Aida</subfield>
   <subfield code="u">Institute of Metrology of Bosnia and Herzegovina - IMBIH, Dolina 6, Sarajevo, Bosnia and Herzegovina</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Suljagic</subfield>
   <subfield code="D">Semsa</subfield>
   <subfield code="u">Institute of Metrology of Bosnia and Herzegovina - IMBIH, Dolina 6, Sarajevo, Bosnia and Herzegovina</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Accreditation and Quality Assurance</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">20/5(2015-10-01), 395-399</subfield>
   <subfield code="x">0949-1775</subfield>
   <subfield code="q">20:5&lt;395</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">20</subfield>
   <subfield code="o">769</subfield>
  </datafield>
 </record>
</collection>
