<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605466246</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100306.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20150401xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s00769-015-1107-6</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s00769-015-1107-6</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Implementation of the calibration's VIM3 definition using the matrix of variance-covariance of input data</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Marc Priel, Michèle Désenfant]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">This paper discusses the effects following the implementation of the concept of calibration presented in the 3rd edition of the international vocabulary of metrology—basic and general concepts and associated terms (VIM) and the repercussions of practitioners adopting VIM3. The new definition leads to modifications in the treatment of calibration data. It is now necessary to establish a relation which allows obtaining any measurement result from any indication of the measuring instrument. This relation takes into account uncertainties and any covariances, both on the values of the standards used and on the indications and maybe even the covariances. The usual statistical technique of regression, the ordinary least squares adjustment, does not generally enable to reach this goal. As a result, more sophisticated methods need to be used, for instance the Generalised Gauss Markov Regression. We compared both methods on a gas chromatograph calibration example.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer-Verlag Berlin Heidelberg, 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Calibration</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Metrological terminology</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">VIM</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Ordinary least squares (OLS)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Generalised Gauss Markov Regression (GGMR)</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Measurement uncertainty</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Variance-covariance matrix</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Priel</subfield>
   <subfield code="D">Marc</subfield>
   <subfield code="u">Laboratoire national de métrologie et d'essais, 1 rue Gaston Boissier, 75724, Paris, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Désenfant</subfield>
   <subfield code="D">Michèle</subfield>
   <subfield code="u">Laboratoire national de métrologie et d'essais, 1 rue Gaston Boissier, 75724, Paris, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Accreditation and Quality Assurance</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">20/2(2015-04-01), 107-114</subfield>
   <subfield code="x">0949-1775</subfield>
   <subfield code="q">20:2&lt;107</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">20</subfield>
   <subfield code="o">769</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s00769-015-1107-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s00769-015-1107-6</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Priel</subfield>
   <subfield code="D">Marc</subfield>
   <subfield code="u">Laboratoire national de métrologie et d'essais, 1 rue Gaston Boissier, 75724, Paris, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Désenfant</subfield>
   <subfield code="D">Michèle</subfield>
   <subfield code="u">Laboratoire national de métrologie et d'essais, 1 rue Gaston Boissier, 75724, Paris, France</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Accreditation and Quality Assurance</subfield>
   <subfield code="d">Springer Berlin Heidelberg</subfield>
   <subfield code="g">20/2(2015-04-01), 107-114</subfield>
   <subfield code="x">0949-1775</subfield>
   <subfield code="q">20:2&lt;107</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">20</subfield>
   <subfield code="o">769</subfield>
  </datafield>
 </record>
</collection>
