A giant magnetoimpedance-based biosensor for sensitive detection of Escherichia coli O157:H7

Verfasser / Beitragende:
[Zhen Yang, Xue-cheng Sun, Tao Wang, Chong Lei, Yan Liu, Yong Zhou, Jian Lei]
Ort, Verlag, Jahr:
2015
Enthalten in:
Biomedical Microdevices, 17/1(2015-02-01), 1-8
Format:
Artikel (online)
ID: 605479429
LEADER caa a22 4500
001 605479429
003 CHVBK
005 20210128100410.0
007 cr unu---uuuuu
008 210128e20150201xx s 000 0 eng
024 7 0 |a 10.1007/s10544-014-9925-6  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10544-014-9925-6 
245 0 2 |a A giant magnetoimpedance-based biosensor for sensitive detection of Escherichia coli O157:H7  |h [Elektronische Daten]  |c [Zhen Yang, Xue-cheng Sun, Tao Wang, Chong Lei, Yan Liu, Yong Zhou, Jian Lei] 
520 3 |a A giant magnetoimpedance (GMI)-based biosensor was developed for detection of Escherichia coli (E. coli) O157: H7. The GMI sensor involving the sensing elements of Cr/Cu/NiFe/Cu/NiFe was fabricated by Micro Electro-Mechanical system (MEMS) technology, including thick photoresist lithography and electroplating. A separate Au film substrate as immunoplatform was used to capture E. coli O157:H7. The monoclonal mouse anti-E. coli antibody was immobilized on Au film substrate surface with a self-assembled layer. The different concentration E. coli O157:H7 (100, 300 and 500cfu/ml) were combined with Dynabeads-antibody conjugates (DAC) respectively. DAC were prepared by conjugating streptavidin-coupled Dynabeads with biotin-labeled polyclonal mouse anti-E. coli antibodies. The classical sandwich assay was used for detection of E. coli O157:H7 targeted with Dynabeads by using antibody-antigen pair combination of biotin-streptavidin. The fundamental principle for detection of E. coli O157:H7 based on GMI sensor was that Dynabeads were employed as magnetic labels of E. coli O157:H7, and E. coli O157:H7 can be monitored by detecting the fringe field of Dynabeads using magnetic sensing elements. We observed that the GMI ratio were significantly improved due to the presence of E. coli O157:H7 combined with Dynabeads. The GMI ratio increased as the E. coli O157:H7 concentration increased. A lower detectable concentration of 100cfu/ml was achieved in present work. The GMI-based biosensor provides a new method to rapid and sensitive detection E. coli O157:H7, which has a large potential for bio-application. 
540 |a Springer Science+Business Media New York, 2015 
690 7 |a E. coli O157:H7  |2 nationallicence 
690 7 |a Giant magnetoimpedance  |2 nationallicence 
690 7 |a Biosensor  |2 nationallicence 
690 7 |a Dynabeads  |2 nationallicence 
690 7 |a Au film  |2 nationallicence 
700 1 |a Yang  |D Zhen  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
700 1 |a Sun  |D Xue-cheng  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
700 1 |a Wang  |D Tao  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
700 1 |a Lei  |D Chong  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
700 1 |a Liu  |D Yan  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
700 1 |a Zhou  |D Yong  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
700 1 |a Lei  |D Jian  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
773 0 |t Biomedical Microdevices  |d Springer US; http://www.springer-ny.com  |g 17/1(2015-02-01), 1-8  |x 1387-2176  |q 17:1<1  |1 2015  |2 17  |o 10544 
856 4 0 |u https://doi.org/10.1007/s10544-014-9925-6  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10544-014-9925-6  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Yang  |D Zhen  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Sun  |D Xue-cheng  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Wang  |D Tao  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Lei  |D Chong  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Liu  |D Yan  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Zhou  |D Yong  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Lei  |D Jian  |u Key Laboratory for Thin Film and Microfabrication of the Ministry of Education, Department of Micro/Nano Electronics, School of electronic information and electrical engineering, Shanghai Jiao Tong University, Dongchuan Road 800, 200240, Shanghai, People's Republic of China  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedical Microdevices  |d Springer US; http://www.springer-ny.com  |g 17/1(2015-02-01), 1-8  |x 1387-2176  |q 17:1<1  |1 2015  |2 17  |o 10544