<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">605479453</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100410.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20150201xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10544-014-9916-7</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10544-014-9916-7</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Bokeh microscopy-enabled microfluidic channels for facile point-of-care monitoring</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Jungwook Paek, Jaeyoun Kim]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">We report the implementation of the bokeh microscopy scheme in microfluidic settings for future applications in point-of-care microchannel monitoring in highly resource-limited environments. We realize the functional integration using a single polymer microlens fabricated over the microchannel. The inherent simplicity of the bokeh microscopy enables image capturing with an off-the-shelf camera. Our pilot devices exhibit 10 ∼ 40 of magnification and 67 ∼ 252μm of field-of-view extent, confirming their utility for monitoring 50 ∼ 100μm microchannels carrying 10 ∼ 50μm objects.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Science+Business Media New York, 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Point-of-care</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Microscopy</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Optofluidics</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Microfluidics</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Paek</subfield>
   <subfield code="D">Jungwook</subfield>
   <subfield code="u">Department of Electrical and Computer Engineering, Iowa State University, 50011, Ames, IA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Kim</subfield>
   <subfield code="D">Jaeyoun</subfield>
   <subfield code="u">Department of Electrical and Computer Engineering, Iowa State University, 50011, Ames, IA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Biomedical Microdevices</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">17/1(2015-02-01), 1-5</subfield>
   <subfield code="x">1387-2176</subfield>
   <subfield code="q">17:1&lt;1</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">17</subfield>
   <subfield code="o">10544</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10544-014-9916-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10544-014-9916-7</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Paek</subfield>
   <subfield code="D">Jungwook</subfield>
   <subfield code="u">Department of Electrical and Computer Engineering, Iowa State University, 50011, Ames, IA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Kim</subfield>
   <subfield code="D">Jaeyoun</subfield>
   <subfield code="u">Department of Electrical and Computer Engineering, Iowa State University, 50011, Ames, IA, USA</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Biomedical Microdevices</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">17/1(2015-02-01), 1-5</subfield>
   <subfield code="x">1387-2176</subfield>
   <subfield code="q">17:1&lt;1</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">17</subfield>
   <subfield code="o">10544</subfield>
  </datafield>
 </record>
</collection>
