A complementary method to CD4 counting: measurement of CD4+/CD8+ T lymphocyte ratio in a tandem affinity microfluidic system

Verfasser / Beitragende:
[Wenjie Li, Yan Gao, Dimitri Pappas]
Ort, Verlag, Jahr:
2015
Enthalten in:
Biomedical Microdevices, 17/6(2015-12-01), 1-9
Format:
Artikel (online)
ID: 605479577
LEADER caa a22 4500
001 605479577
003 CHVBK
005 20210128100410.0
007 cr unu---uuuuu
008 210128e20151201xx s 000 0 eng
024 7 0 |a 10.1007/s10544-015-0023-1  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10544-015-0023-1 
245 0 2 |a A complementary method to CD4 counting: measurement of CD4+/CD8+ T lymphocyte ratio in a tandem affinity microfluidic system  |h [Elektronische Daten]  |c [Wenjie Li, Yan Gao, Dimitri Pappas] 
520 3 |a We describe a tandem affinity microfluidic separation that measures the ratio of CD4+/CD8+ T lymphocytes from blood samples. It is performed by injecting 2μL of lysed blood samples at 1800-2700cellsμL-1 into a microfluidic device containing two serially linked affinity regions, followed with a stop flow incubation that captures CD4+/CD8+ T lymphocytes on the corresponding affinity regions. Fluorophore conjugated antibodies are then injected at a controlled shear stress of 1.7dyn cm-2 to label target cells while eluting non-specific cells; and at last the CD4/CD8 ratio is calculated after the cell enumeration. The ratio of CD4+/CD8+ T lymphocytes achieved by our tandem affinity microfluidic system was in close agreement with that performed using conventional flow cytometry (R 2  = 0.97) over a wide range (0.4-2.5) that covered the reference values from immune deficient patients to healthy people. This approach may represent an inexpensive and powerful tool in diagnosis of immunodeficiency disorders including HIV or mycobacterium tuberculosis. 
540 |a Springer Science+Business Media New York, 2015 
690 7 |a Tandem affinity microfluidic separation  |2 nationallicence 
690 7 |a Blood cells  |2 nationallicence 
690 7 |a CD4+/CD8 + T lymphocytes  |2 nationallicence 
690 7 |a CD4/CD8 ratio  |2 nationallicence 
690 7 |a Cytometry  |2 nationallicence 
700 1 |a Li  |D Wenjie  |u Department of Chemistry and Biochemistry, Texas Tech University, 79409, Lubbock, TX, USA  |4 aut 
700 1 |a Gao  |D Yan  |u Department of Chemistry and Biochemistry, Texas Tech University, 79409, Lubbock, TX, USA  |4 aut 
700 1 |a Pappas  |D Dimitri  |u Department of Chemistry and Biochemistry, Texas Tech University, 79409, Lubbock, TX, USA  |4 aut 
773 0 |t Biomedical Microdevices  |d Springer US; http://www.springer-ny.com  |g 17/6(2015-12-01), 1-9  |x 1387-2176  |q 17:6<1  |1 2015  |2 17  |o 10544 
856 4 0 |u https://doi.org/10.1007/s10544-015-0023-1  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10544-015-0023-1  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Li  |D Wenjie  |u Department of Chemistry and Biochemistry, Texas Tech University, 79409, Lubbock, TX, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Gao  |D Yan  |u Department of Chemistry and Biochemistry, Texas Tech University, 79409, Lubbock, TX, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Pappas  |D Dimitri  |u Department of Chemistry and Biochemistry, Texas Tech University, 79409, Lubbock, TX, USA  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedical Microdevices  |d Springer US; http://www.springer-ny.com  |g 17/6(2015-12-01), 1-9  |x 1387-2176  |q 17:6<1  |1 2015  |2 17  |o 10544