A simple microfluidic device for the deformability assessment of blood cells in a continuous flow

Verfasser / Beitragende:
[Raquel Rodrigues, Diana Pinho, Vera Faustino, Rui Lima]
Ort, Verlag, Jahr:
2015
Enthalten in:
Biomedical Microdevices, 17/6(2015-12-01), 1-9
Format:
Artikel (online)
ID: 605479631
LEADER caa a22 4500
001 605479631
003 CHVBK
005 20210128100411.0
007 cr unu---uuuuu
008 210128e20151201xx s 000 0 eng
024 7 0 |a 10.1007/s10544-015-0014-2  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10544-015-0014-2 
245 0 2 |a A simple microfluidic device for the deformability assessment of blood cells in a continuous flow  |h [Elektronische Daten]  |c [Raquel Rodrigues, Diana Pinho, Vera Faustino, Rui Lima] 
520 3 |a Blood flow presents several interesting phenomena in microcirculation that can be used to develop microfluidic devices capable to promote blood cells separation and analysis in continuous flow. In the last decade there have been numerous microfluidic studies focused on the deformation of red blood cells (RBCs) flowing through geometries mimicking microvessels. In contrast, studies focusing on the deformation of white blood cells (WBCs) are scarce despite this phenomenon often happens in the microcirculation. In this work, we present a novel integrative microfluidic device able to perform continuous separation of a desired amount of blood cells, without clogging or jamming, and at the same time, capable to assess the deformation index (DI) of both WBCs and RBCs. To determine the DI of both WBCs and RBCs, a hyperbolic converging microchannel was used, as well as a suitable image analysis technique to measure the DIs of these blood cells along the regions of interest. The results show that the WBCs have a much lower deformability than RBCs when subjected to the same in vitro flow conditions, which is directly related to their cytoskeleton and nucleus contents. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to simultaneously separate and assess blood cells deformability. 
540 |a Springer Science+Business Media New York, 2015 
690 7 |a Microfluidic devices  |2 nationallicence 
690 7 |a Cell separation and deformability  |2 nationallicence 
690 7 |a Hyperbolic microchannel  |2 nationallicence 
690 7 |a Blood on chips  |2 nationallicence 
690 7 |a RBC  |2 nationallicence 
690 7 |a WBC  |2 nationallicence 
700 1 |a Rodrigues  |D Raquel  |u LCM - Laboratory of Catalysis and Materials - Associate Laboratory LSRE/LCM, Faculdade de Engenharia, da Universidade do Porto (FEUP), R. Dr. Roberto Frias, 4200-465, Porto, Portugal  |4 aut 
700 1 |a Pinho  |D Diana  |u Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857, Bragança, Portugal  |4 aut 
700 1 |a Faustino  |D Vera  |u Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857, Bragança, Portugal  |4 aut 
700 1 |a Lima  |D Rui  |u Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857, Bragança, Portugal  |4 aut 
773 0 |t Biomedical Microdevices  |d Springer US; http://www.springer-ny.com  |g 17/6(2015-12-01), 1-9  |x 1387-2176  |q 17:6<1  |1 2015  |2 17  |o 10544 
856 4 0 |u https://doi.org/10.1007/s10544-015-0014-2  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10544-015-0014-2  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Rodrigues  |D Raquel  |u LCM - Laboratory of Catalysis and Materials - Associate Laboratory LSRE/LCM, Faculdade de Engenharia, da Universidade do Porto (FEUP), R. Dr. Roberto Frias, 4200-465, Porto, Portugal  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Pinho  |D Diana  |u Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857, Bragança, Portugal  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Faustino  |D Vera  |u Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857, Bragança, Portugal  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Lima  |D Rui  |u Polytechnic Institute of Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857, Bragança, Portugal  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedical Microdevices  |d Springer US; http://www.springer-ny.com  |g 17/6(2015-12-01), 1-9  |x 1387-2176  |q 17:6<1  |1 2015  |2 17  |o 10544