PicoMolar level detection of protein biomarkers based on electronic sizing of bead aggregates: theoretical and experimental considerations
Gespeichert in:
Verfasser / Beitragende:
[Z. Lin, X. Cao, P. Xie, M. Liu, Mehdi Javanmard]
Ort, Verlag, Jahr:
2015
Enthalten in:
Biomedical Microdevices, 17/6(2015-12-01), 1-7
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605479658 | ||
| 003 | CHVBK | ||
| 005 | 20210128100411.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20151201xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s10544-015-0022-2 |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s10544-015-0022-2 | ||
| 245 | 0 | 0 | |a PicoMolar level detection of protein biomarkers based on electronic sizing of bead aggregates: theoretical and experimental considerations |h [Elektronische Daten] |c [Z. Lin, X. Cao, P. Xie, M. Liu, Mehdi Javanmard] |
| 520 | 3 | |a We demonstrate a novel method for electronically detecting and quantifying protein biomarkers using microfluidic impedance cytometry. Our biosensor, which consists of gold electrodes micro-fabricated in a microchannel, detects the differences between bead aggregates of varying sizes in a micro-pore sandwiched between two micro channels. We perform a sandwich immunoassay, where the complementary antibody pairs are immobilized on two different bead types, and the presence of antigen results in bead aggregation, the amount of which depends on antigen quantity. When single beads or bead aggregates pass through the impedance sensor, differences in impedance change are detected. In this manuscript, we perform a comprehensive theoretical study on the limits imposed on sensitivity of this technique due to electronic noise and also mass transfer and reaction limits. We also experimentally characterize the performance of this technique by validating the technique on an IgG detection assay. A detection limit at the picoMolar level is demonstrated, thus comparable in sensitivity to a sandwich ELISA. | |
| 540 | |a Springer Science+Business Media New York, 2015 | ||
| 690 | 7 | |a Protein biomarker detection |2 nationallicence | |
| 690 | 7 | |a Microfluidics |2 nationallicence | |
| 690 | 7 | |a Impedance Cytometry |2 nationallicence | |
| 700 | 1 | |a Lin |D Z. |u Rutgers, The State University Of New Jersey, 08854, Piscataway, NJ, USA |4 aut | |
| 700 | 1 | |a Cao |D X. |u Rutgers, The State University Of New Jersey, 08854, Piscataway, NJ, USA |4 aut | |
| 700 | 1 | |a Xie |D P. |u Rutgers, The State University Of New Jersey, 08854, Piscataway, NJ, USA |4 aut | |
| 700 | 1 | |a Liu |D M. |u Rutgers, The State University Of New Jersey, 08854, Piscataway, NJ, USA |4 aut | |
| 700 | 1 | |a Javanmard |D Mehdi |u Rutgers, The State University Of New Jersey, 08854, Piscataway, NJ, USA |4 aut | |
| 773 | 0 | |t Biomedical Microdevices |d Springer US; http://www.springer-ny.com |g 17/6(2015-12-01), 1-7 |x 1387-2176 |q 17:6<1 |1 2015 |2 17 |o 10544 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s10544-015-0022-2 |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a research-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s10544-015-0022-2 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Lin |D Z. |u Rutgers, The State University Of New Jersey, 08854, Piscataway, NJ, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Cao |D X. |u Rutgers, The State University Of New Jersey, 08854, Piscataway, NJ, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Xie |D P. |u Rutgers, The State University Of New Jersey, 08854, Piscataway, NJ, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Liu |D M. |u Rutgers, The State University Of New Jersey, 08854, Piscataway, NJ, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Javanmard |D Mehdi |u Rutgers, The State University Of New Jersey, 08854, Piscataway, NJ, USA |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Biomedical Microdevices |d Springer US; http://www.springer-ny.com |g 17/6(2015-12-01), 1-7 |x 1387-2176 |q 17:6<1 |1 2015 |2 17 |o 10544 | ||