Wireless programmable electrochemical drug delivery micropump with fully integrated electrochemical dosing sensors

Verfasser / Beitragende:
[Roya Sheybani, Angelica Cobo, Ellis Meng]
Ort, Verlag, Jahr:
2015
Enthalten in:
Biomedical Microdevices, 17/4(2015-08-01), 1-13
Format:
Artikel (online)
ID: 605479984
LEADER caa a22 4500
001 605479984
003 CHVBK
005 20210128100412.0
007 cr unu---uuuuu
008 210128e20150801xx s 000 0 eng
024 7 0 |a 10.1007/s10544-015-9980-7  |2 doi 
035 |a (NATIONALLICENCE)springer-10.1007/s10544-015-9980-7 
245 0 0 |a Wireless programmable electrochemical drug delivery micropump with fully integrated electrochemical dosing sensors  |h [Elektronische Daten]  |c [Roya Sheybani, Angelica Cobo, Ellis Meng] 
520 3 |a We present a fully integrated implantable electrolysis-based micropump with incorporated EI dosing sensors. Wireless powering and data telemetry (through amplitude and frequency modulation) were utilized to achieve variable flow control and a bi-directional data link with the sensors. Wireless infusion rate control (0.14-1.04μL/min) and dose sensing (bolus resolution of 0.55-2μL) were each calibrated separately with the final circuit architecture and then simultaneous wireless flow control and dose sensing were demonstrated. Recombination detection using the dosing system, as well as, effects of coil separation distance and misalignment in wireless power and data transfer were studied. A custom-made normally closed spring-loaded ball check valve was designed and incorporated at the reservoir outlet to prevent backflow of fluids as a result of the reverse pressure gradient caused by recombination of electrolysis gases. Successful delivery, infusion rate control, and dose sensing were achieved in simulated brain tissue. 
540 |a Springer Science+Business Media New York, 2015 
690 7 |a Electrolysis micropump  |2 nationallicence 
690 7 |a Electrochemical sensors  |2 nationallicence 
690 7 |a Patient-tailored drug delivery  |2 nationallicence 
690 7 |a Dosing accuracy  |2 nationallicence 
690 7 |a Check valve  |2 nationallicence 
700 1 |a Sheybani  |D Roya  |u Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, 1042 Downey Way, DRB-140, 90089-1111, Los Angeles, CA, USA  |4 aut 
700 1 |a Cobo  |D Angelica  |u Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, 1042 Downey Way, DRB-140, 90089-1111, Los Angeles, CA, USA  |4 aut 
700 1 |a Meng  |D Ellis  |u Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, 1042 Downey Way, DRB-140, 90089-1111, Los Angeles, CA, USA  |4 aut 
773 0 |t Biomedical Microdevices  |d Springer US; http://www.springer-ny.com  |g 17/4(2015-08-01), 1-13  |x 1387-2176  |q 17:4<1  |1 2015  |2 17  |o 10544 
856 4 0 |u https://doi.org/10.1007/s10544-015-9980-7  |q text/html  |z Onlinezugriff via DOI 
898 |a BK010053  |b XK010053  |c XK010000 
900 7 |a Metadata rights reserved  |b Springer special CC-BY-NC licence  |2 nationallicence 
908 |D 1  |a research-article  |2 jats 
949 |B NATIONALLICENCE  |F NATIONALLICENCE  |b NL-springer 
950 |B NATIONALLICENCE  |P 856  |E 40  |u https://doi.org/10.1007/s10544-015-9980-7  |q text/html  |z Onlinezugriff via DOI 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Sheybani  |D Roya  |u Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, 1042 Downey Way, DRB-140, 90089-1111, Los Angeles, CA, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Cobo  |D Angelica  |u Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, 1042 Downey Way, DRB-140, 90089-1111, Los Angeles, CA, USA  |4 aut 
950 |B NATIONALLICENCE  |P 700  |E 1-  |a Meng  |D Ellis  |u Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, 1042 Downey Way, DRB-140, 90089-1111, Los Angeles, CA, USA  |4 aut 
950 |B NATIONALLICENCE  |P 773  |E 0-  |t Biomedical Microdevices  |d Springer US; http://www.springer-ny.com  |g 17/4(2015-08-01), 1-13  |x 1387-2176  |q 17:4<1  |1 2015  |2 17  |o 10544