Influence of surface modification and static pressure on microdialysis protein extraction efficiency
Gespeichert in:
Verfasser / Beitragende:
[Jiangtao Chu, Torgny Undin, Sara Lind, Klas Hjort, Andreas Dahlin]
Ort, Verlag, Jahr:
2015
Enthalten in:
Biomedical Microdevices, 17/5(2015-10-01), 1-11
Format:
Artikel (online)
Online Zugang:
| LEADER | caa a22 4500 | ||
|---|---|---|---|
| 001 | 605480109 | ||
| 003 | CHVBK | ||
| 005 | 20210128100413.0 | ||
| 007 | cr unu---uuuuu | ||
| 008 | 210128e20151001xx s 000 0 eng | ||
| 024 | 7 | 0 | |a 10.1007/s10544-015-0005-3 |2 doi |
| 035 | |a (NATIONALLICENCE)springer-10.1007/s10544-015-0005-3 | ||
| 245 | 0 | 0 | |a Influence of surface modification and static pressure on microdialysis protein extraction efficiency |h [Elektronische Daten] |c [Jiangtao Chu, Torgny Undin, Sara Lind, Klas Hjort, Andreas Dahlin] |
| 520 | 3 | |a There is growing interest in using microdialysis (MD) for monitoring larger and more complex molecules such as neuropeptides and proteins. This promotes the use of MD membranes with molecular weight cut off (MWCO) of 100kDa or above. The hydrodynamic property of the membrane goes to ultrafiltration or beyond, making the MD catheters more sensitive to pressure. In the meantime, despite the large pore size, studies have shown that membrane biofouling still lead to unstable catheter performance. The objective is to study in vitro how 500kDa dextran and Poloxamer 407 surface modification affect the fluid recovery (FR) and extraction efficiency (EE) of 100kDa MWCO MD catheters. A pressure chamber was designed to facilitate the tests, using as MD sample a protein standard with similar concentrations as in human cerebral spinal fluid, comparing native and Poloxamer 407 modified MD catheters. The collected dialysate fractions were examined for FR and protein EE, employing Dot-it Spot-it Protein Assay for total protein EE and targeted mass spectrometry (MS) for EE of individual proteins and peptides. The FR results suggested that the surface modified catheters were less sensitive to the pressure and provide higher precision, and provided a FR closer to 100%. The surface modification did not show a significant effect on the protein EE. The average total protein EE of surface modified catheters was slightly higher than that of the native ones. The MS EE data of individual proteins showed a clear trend of complex response in EE with pressure. | |
| 540 | |a Springer Science+Business Media New York, 2015 | ||
| 690 | 7 | |a Microdialysis |2 nationallicence | |
| 690 | 7 | |a Surface modification |2 nationallicence | |
| 690 | 7 | |a Poloxamer |2 nationallicence | |
| 690 | 7 | |a Protein |2 nationallicence | |
| 690 | 7 | |a Extraction efficiency |2 nationallicence | |
| 700 | 1 | |a Chu |D Jiangtao |u Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21, Uppsala, Sweden |4 aut | |
| 700 | 1 | |a Undin |D Torgny |u Department of Chemistry-BMC, Analytical Chemistry and Science for Life Laboratory, Uppsala University, Box 599, SE-751 24, Uppsala, Sweden |4 aut | |
| 700 | 1 | |a Lind |D Sara |u Department of Chemistry-BMC, Analytical Chemistry and Science for Life Laboratory, Uppsala University, Box 599, SE-751 24, Uppsala, Sweden |4 aut | |
| 700 | 1 | |a Hjort |D Klas |u Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21, Uppsala, Sweden |4 aut | |
| 700 | 1 | |a Dahlin |D Andreas |u Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21, Uppsala, Sweden |4 aut | |
| 773 | 0 | |t Biomedical Microdevices |d Springer US; http://www.springer-ny.com |g 17/5(2015-10-01), 1-11 |x 1387-2176 |q 17:5<1 |1 2015 |2 17 |o 10544 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/s10544-015-0005-3 |q text/html |z Onlinezugriff via DOI |
| 898 | |a BK010053 |b XK010053 |c XK010000 | ||
| 900 | 7 | |a Metadata rights reserved |b Springer special CC-BY-NC licence |2 nationallicence | |
| 908 | |D 1 |a research-article |2 jats | ||
| 949 | |B NATIONALLICENCE |F NATIONALLICENCE |b NL-springer | ||
| 950 | |B NATIONALLICENCE |P 856 |E 40 |u https://doi.org/10.1007/s10544-015-0005-3 |q text/html |z Onlinezugriff via DOI | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Chu |D Jiangtao |u Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21, Uppsala, Sweden |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Undin |D Torgny |u Department of Chemistry-BMC, Analytical Chemistry and Science for Life Laboratory, Uppsala University, Box 599, SE-751 24, Uppsala, Sweden |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Lind |D Sara |u Department of Chemistry-BMC, Analytical Chemistry and Science for Life Laboratory, Uppsala University, Box 599, SE-751 24, Uppsala, Sweden |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Hjort |D Klas |u Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21, Uppsala, Sweden |4 aut | ||
| 950 | |B NATIONALLICENCE |P 700 |E 1- |a Dahlin |D Andreas |u Department of Engineering Sciences, Uppsala University, Box 534, SE-751 21, Uppsala, Sweden |4 aut | ||
| 950 | |B NATIONALLICENCE |P 773 |E 0- |t Biomedical Microdevices |d Springer US; http://www.springer-ny.com |g 17/5(2015-10-01), 1-11 |x 1387-2176 |q 17:5<1 |1 2015 |2 17 |o 10544 | ||