<?xml version="1.0" encoding="UTF-8"?>
<collection xmlns="http://www.loc.gov/MARC21/slim">
 <record>
  <leader>     caa a22        4500</leader>
  <controlfield tag="001">60548015X</controlfield>
  <controlfield tag="003">CHVBK</controlfield>
  <controlfield tag="005">20210128100413.0</controlfield>
  <controlfield tag="007">cr unu---uuuuu</controlfield>
  <controlfield tag="008">210128e20151001xx      s     000 0 eng  </controlfield>
  <datafield tag="024" ind1="7" ind2="0">
   <subfield code="a">10.1007/s10544-015-9982-5</subfield>
   <subfield code="2">doi</subfield>
  </datafield>
  <datafield tag="035" ind1=" " ind2=" ">
   <subfield code="a">(NATIONALLICENCE)springer-10.1007/s10544-015-9982-5</subfield>
  </datafield>
  <datafield tag="245" ind1="0" ind2="0">
   <subfield code="a">Novel scalable and monolithically integrated extracorporeal gas exchange device</subfield>
   <subfield code="h">[Elektronische Daten]</subfield>
   <subfield code="c">[Tina Rieper, Claas Müller, Holger Reinecke]</subfield>
  </datafield>
  <datafield tag="520" ind1="3" ind2=" ">
   <subfield code="a">A novel extracorporeal gas exchange device (EGED) is developed, implemented and characterized. The aim hereby is to overcome drawbacks of state-of-the-art devices and of state-of-science approaches, like their labor intensive fabrication and their low volume density of the gas exchange area, respectively. As a consequence of the stacked setup of alternating layers of the blood compartment and the ventilation gas compartment, the developed EGED allows for double sided gas exchange. Furthermore, it enables an adaption to the diversity of medical requirements by scaling the amount of layers. The developed fabrication chain is used to fabricate leakage-free evaluation models and allows for a transition to automated fabrication. The EGED is completely fabricated in polydimethylsiloxane (PDMS) and features diffusion membranes, which are separating the compartments, with a mean thickness of 90μm. With the evaluation models and oxygen as ventilation gas an oxygen transfer of 60ml/lblood (25ml/(minm2)) and a carbon dioxide transfer of 70ml/lblood (30ml/(minm2)) are achieved. The linear scalability of the concept as well as the functionality of the EGED with air as ventilation gas is shown.</subfield>
  </datafield>
  <datafield tag="540" ind1=" " ind2=" ">
   <subfield code="a">Springer Science+Business Media New York, 2015</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Extracorporeal gas exchange</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Silicone rubber processing</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Gas transfer simulation</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Large area bonding of microstructured PDMS sheets</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="690" ind1=" " ind2="7">
   <subfield code="a">Microstructured, thin PDMS sheets</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Rieper</subfield>
   <subfield code="D">Tina</subfield>
   <subfield code="u">Laboratory for Process Technology, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110, Freiburg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Müller</subfield>
   <subfield code="D">Claas</subfield>
   <subfield code="u">Laboratory for Process Technology, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110, Freiburg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="700" ind1="1" ind2=" ">
   <subfield code="a">Reinecke</subfield>
   <subfield code="D">Holger</subfield>
   <subfield code="u">Laboratory for Process Technology, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110, Freiburg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="773" ind1="0" ind2=" ">
   <subfield code="t">Biomedical Microdevices</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">17/5(2015-10-01), 1-10</subfield>
   <subfield code="x">1387-2176</subfield>
   <subfield code="q">17:5&lt;1</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">17</subfield>
   <subfield code="o">10544</subfield>
  </datafield>
  <datafield tag="856" ind1="4" ind2="0">
   <subfield code="u">https://doi.org/10.1007/s10544-015-9982-5</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="898" ind1=" " ind2=" ">
   <subfield code="a">BK010053</subfield>
   <subfield code="b">XK010053</subfield>
   <subfield code="c">XK010000</subfield>
  </datafield>
  <datafield tag="900" ind1=" " ind2="7">
   <subfield code="a">Metadata rights reserved</subfield>
   <subfield code="b">Springer special CC-BY-NC licence</subfield>
   <subfield code="2">nationallicence</subfield>
  </datafield>
  <datafield tag="908" ind1=" " ind2=" ">
   <subfield code="D">1</subfield>
   <subfield code="a">research-article</subfield>
   <subfield code="2">jats</subfield>
  </datafield>
  <datafield tag="949" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="F">NATIONALLICENCE</subfield>
   <subfield code="b">NL-springer</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">856</subfield>
   <subfield code="E">40</subfield>
   <subfield code="u">https://doi.org/10.1007/s10544-015-9982-5</subfield>
   <subfield code="q">text/html</subfield>
   <subfield code="z">Onlinezugriff via DOI</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Rieper</subfield>
   <subfield code="D">Tina</subfield>
   <subfield code="u">Laboratory for Process Technology, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110, Freiburg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Müller</subfield>
   <subfield code="D">Claas</subfield>
   <subfield code="u">Laboratory for Process Technology, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110, Freiburg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">700</subfield>
   <subfield code="E">1-</subfield>
   <subfield code="a">Reinecke</subfield>
   <subfield code="D">Holger</subfield>
   <subfield code="u">Laboratory for Process Technology, Department of Microsystems Engineering - IMTEK, University of Freiburg, Georges-Koehler-Allee 103, 79110, Freiburg, Germany</subfield>
   <subfield code="4">aut</subfield>
  </datafield>
  <datafield tag="950" ind1=" " ind2=" ">
   <subfield code="B">NATIONALLICENCE</subfield>
   <subfield code="P">773</subfield>
   <subfield code="E">0-</subfield>
   <subfield code="t">Biomedical Microdevices</subfield>
   <subfield code="d">Springer US; http://www.springer-ny.com</subfield>
   <subfield code="g">17/5(2015-10-01), 1-10</subfield>
   <subfield code="x">1387-2176</subfield>
   <subfield code="q">17:5&lt;1</subfield>
   <subfield code="1">2015</subfield>
   <subfield code="2">17</subfield>
   <subfield code="o">10544</subfield>
  </datafield>
 </record>
</collection>
